Permit: TR-UTL-0926-01567
Permit Details
Status:
In Review
Type:
Right-of-Way (ROW) - Utility
Address:
5902 E 29TH ST
Address NEW:
5902 E 29TH ST
Apply Date:
09/14/2026
Applicant:
Arnulfo Quiroz
Description:
T169930 - Crews to park in the City of Tucson ROW to replace (11) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (1) pole location. (2) sidewalk to be replaced. 2’x2’ excavations per pole for (3) 35’ S4, (1) 40’ S3 Poles and 3x3 excavations per pole for (5) 45’ S1, (1) 50’ S1, 51’ S1(SSDE) Poles. P1 – 50S1 – 43’ – 15” dia. P2 – 45S1 – 38.5’ – 12” dia. P3 – 45S1 – 38.5’ – 12” dia. P4 – 45S1 – 38.5’ – 12” dia. P5 – 51’SS – 37.5’ – 26” dia. P6 – 45S1 – 38.5’ – 12” dia. P7 – 40S3 – 34’ – 12” dia. P8 – 35S4 – 29.5’ – 11” dia. P9 – 35S4 – 29.5’ – 11” dia. P10 – 35S4 – 29.5’ – 11” dia. P11 – 45S1 – 38.5’ – 12” dia.
Permit Reviews
Permit Number - TR-UTL-0926-01567
Permit Status: In review
Permit Description: T169930 - Crews to park in the City of Tucson ROW to replace (11) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (1) pole location. (2) sidewalk to be replaced. 2’x2’ excavations per pole for (3) 35’ S4, (1) 40’ S3 Poles and 3x3 excavations per pole for (5) 45’ S1, (1) 50’ S1, 51’ S1(SSDE) Poles.
P1 – 50S1 – 43’ – 15” dia.
P2 – 45S1 – 38.5’ – 12” dia.
P3 – 45S1 – 38.5’ – 12” dia.
P4 – 45S1 – 38.5’ – 12” dia.
P5 – 51’SS – 37.5’ – 26” dia.
P6 – 45S1 – 38.5’ – 12” dia.
P7 – 40S3 – 34’ – 12” dia.
P8 – 35S4 – 29.5’ – 11” dia.
P9 – 35S4 – 29.5’ – 11” dia.
P10 – 35S4 – 29.5’ – 11” dia.
P11 – 45S1 – 38.5’ – 12” dia.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/30/2026 | RIGHT-OF-WAY REVIEW v.2 | 09/30/2026 | REQUIRES RESUBMIT |
| 09/15/2026 | RIGHT-OF-WAY REVIEW v.1 | 09/28/2026 | REQUIRES RESUBMIT |
| 10/05/2026 | RIGHT-OF-WAY REVIEW v.3 | N/A | IN REVIEW |
Outstanding Activity Conditions
Permit Number - TR-UTL-0926-01567
Permit Status: In review
Permit Description: T169930 - Crews to park in the City of Tucson ROW to replace (11) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (1) pole location. (2) sidewalk to be replaced. 2’x2’ excavations per pole for (3) 35’ S4, (1) 40’ S3 Poles and 3x3 excavations per pole for (5) 45’ S1, (1) 50’ S1, 51’ S1(SSDE) Poles.
P1 – 50S1 – 43’ – 15” dia.
P2 – 45S1 – 38.5’ – 12” dia.
P3 – 45S1 – 38.5’ – 12” dia.
P4 – 45S1 – 38.5’ – 12” dia.
P5 – 51’SS – 37.5’ – 26” dia.
P6 – 45S1 – 38.5’ – 12” dia.
P7 – 40S3 – 34’ – 12” dia.
P8 – 35S4 – 29.5’ – 11” dia.
P9 – 35S4 – 29.5’ – 11” dia.
P10 – 35S4 – 29.5’ – 11” dia.
P11 – 45S1 – 38.5’ – 12” dia.
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 09/15/2026 | **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 09/15/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 09/15/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |