Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
455 W MCIVER PL
Address NEW:
455 W MCIVER PL
Apply Date:
09/01/2026
Applicant:
Arnulfo Quiroz
Description:
T159495 - Crews to park in the City of Tucson ROW to replace (13) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (2) pole locations. No sidewalk impact. 2’x2’ excavations per pole and 3x3 excavations for (6) 55’ SH3 Poles. Continuation of TR-UTL-0326-00575

Permit Reviews

Permit Number - TR-UTL-0926-01488
Permit Status: Inspections
Permit Description: T159495 - Crews to park in the City of Tucson ROW to replace (13) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (2) pole locations. No sidewalk impact. 2’x2’ excavations per pole and 3x3 excavations for (6) 55’ SH3 Poles. Continuation of TR-UTL-0326-00575
Start Date Submittal Complete Date Status  
09/01/2026 RIGHT-OF-WAY REVIEW v.1 09/18/2026 REQUIRES RESUBMIT Review Details
09/22/2026 RIGHT-OF-WAY REVIEW v.2 09/24/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0926-01488
Permit Status: Inspections
Permit Description: T159495 - Crews to park in the City of Tucson ROW to replace (13) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (2) pole locations. No sidewalk impact. 2’x2’ excavations per pole and 3x3 excavations for (6) 55’ SH3 Poles. Continuation of TR-UTL-0326-00575
Total Outstanding Activity Conditions - 6
Date Name
09/02/2026 Notify in writing at least 5 working days before work begins, any businesses, residences and public transit routes affected by your temporary traffic control. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.
09/02/2026 PAVEMENT MORATORIUM
09/02/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
09/02/2026 Traffic Control set-up approved between 7AM - 5PM
09/02/2026 Traffic control set-up approved between 9AM - 3:30PM
09/02/2026 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.

Completed Inspections

Permit Status: Inspections
Permit Number: TR-UTL-0926-01488
Permit Description: T159495 - Crews to park in the City of Tucson ROW to replace (13) TEP poles, OH conductors, and OH attachments. Down guy anchors are to be replaced at (2) pole locations. Risers to be replaced at (2) pole locations. No sidewalk impact. 2’x2’ excavations per pole and 3x3 excavations for (6) 55’ SH3 Poles. Continuation of TR-UTL-0326-00575
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/30/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed Old permit was tr-UTL-0326-00575 this Precon was for this new permit no design changes at the moment
10/19/2026 TRSP - ROW - Backfill - Placement/Compaction Passed replacing utility poles in-service the situation is turned into an emergency and they are going to have to close a section of Alteras between 14th and Oracle today for a couple of hours

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
DB 72300 - 2501 N ORACLE RD - VARIOUS - T159495_V2.PDF DOCUMENTS VIEW
DB 72300 - PAGE 2 - 2501 N ORACLE RD - VARIOUS - T159495_V2.PDF DOCUMENTS VIEW
DPH6 - T159495 - PERMIT MAP_V1.PDF DOCUMENTS VIEW