Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
1790 E RIVER RD
Apply Date:
09/25/2024
Applicant:
Vickie McCambridge
Description:
Tie point will be MB inside existing pedestal. Trench for 85ft at a depth of 3ft. Run 85ft of .625 coax cable. Place new ped and ground rod. Pull 80ft of .625 coax cable through existing conduit. Hand dig 20ft of 2in conduit at a depth of 3ft. Run 20ft of .625 coax. Place new ped and ground rod. Pull 130ft of .625 coax cable through existing conduit.

Permit Reviews

Permit Number - TR-UTL-0924-01848
Permit Status: Complete
Permit Description: Tie point will be MB inside existing pedestal. Trench for 85ft at a depth of 3ft. Run 85ft of .625 coax cable. Place new ped and ground rod. Pull 80ft of .625 coax cable through existing conduit. Hand dig 20ft of 2in conduit at a depth of 3ft. Run 20ft of .625 coax. Place new ped and ground rod. Pull 130ft of .625 coax cable through existing conduit.
Start Date Submittal Complete Date Status  
09/25/2024 RIGHT-OF-WAY REVIEW v.1 09/27/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0924-01848
Permit Status: Complete
Permit Description: Tie point will be MB inside existing pedestal. Trench for 85ft at a depth of 3ft. Run 85ft of .625 coax cable. Place new ped and ground rod. Pull 80ft of .625 coax cable through existing conduit. Hand dig 20ft of 2in conduit at a depth of 3ft. Run 20ft of .625 coax. Place new ped and ground rod. Pull 130ft of .625 coax cable through existing conduit.
Total Outstanding Activity Conditions - 3
Date Name
09/26/2024 Traffic control set-up approved between 9AM - 3:30PM
09/26/2024 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
09/26/2024 BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-0924-01848
Permit Description: Tie point will be MB inside existing pedestal. Trench for 85ft at a depth of 3ft. Run 85ft of .625 coax cable. Place new ped and ground rod. Pull 80ft of .625 coax cable through existing conduit. Hand dig 20ft of 2in conduit at a depth of 3ft. Run 20ft of .625 coax. Place new ped and ground rod. Pull 130ft of .625 coax cable through existing conduit.
Total Completed Inspections - 4
Date Description Inspector Results Comments
11/12/2024 TRSP - ROW - Barricade - Setup/Routine Passed
11/12/2024 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
11/12/2024 TRSP - ROW - Backfill - Placement/Compaction Passed
11/12/2024 TRSP - ROW - Final Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW