Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-UTL-0924-01757
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
10 W COUNCIL ST
Address NEW:
10 W COUNCIL ST
Apply Date:
09/13/2024
Applicant:
CAITLIN RIPLEY - SOUTHWEST BARRICADES
Description:
Cox to pull thru 11' of existing CATV fiver, overlash181' of existing CATV aerial strand, attach 211' of new CATV aerial strand & trench 9' to install new CATV conduit for system tie.
Permit Reviews
Permit Number - TR-UTL-0924-01757
Permit Status: Complete
Permit Description: Cox to pull thru 11' of existing CATV fiver, overlash181' of existing CATV aerial strand, attach 211' of new CATV aerial strand & trench 9' to install new CATV conduit for system tie.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2024 | RIGHT-OF-WAY REVIEW v.1 | 10/18/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0924-01757
Permit Status: Complete
Permit Description: Cox to pull thru 11' of existing CATV fiver, overlash181' of existing CATV aerial strand, attach 211' of new CATV aerial strand & trench 9' to install new CATV conduit for system tie.
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 09/16/2024 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 09/16/2024 | Traffic control set-up approved between 9AM - 3:30PM |
| 09/16/2024 | A NOTICE OF TEMPORARY HOLIDAY RESTRICTION applies to this permit and will be in effect from Thanksgiving Day to January 02. Due to the increasing traffic volume on many of the City’s roads, it is necessary to restrict lane closures on certain roads during the holiday season. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0924-01757
Permit Description: Cox to pull thru 11' of existing CATV fiver, overlash181' of existing CATV aerial strand, attach 211' of new CATV aerial strand & trench 9' to install new CATV conduit for system tie.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 02/18/2025 | TRSP - ROW - Barricade - Setup/Routine | Passed | Traffic control set up was not witnessed, all devices have been removed from site | |
| 02/18/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | Riser ran down pole and backfilled with native soil in landscape area to 85% compaction, completed and approved | |
| 02/18/2025 | TRSP - ROW - Final | Passed | All prior inspections passed, traffic control removed from site, job completed |