Description:
P.360547A Overbuild: Bore 1191' and trench 82' to place conduit and fiber cable Place 1478' of aerial fiber cable Place 14 pedestals/cabinets/vaults
Permit Reviews
Permit Number - TR-UTL-0826-01386
Permit Status: Needs resubmittal
Permit Description: P.360547A Overbuild:
Bore 1191' and trench 82' to place conduit and fiber cable
Place 1478' of aerial fiber cable
Place 14 pedestals/cabinets/vaults
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/19/2026 | RIGHT-OF-WAY REVIEW v.1 | 09/24/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-0826-01386
Permit Status: Needs resubmittal
Permit Description: P.360547A Overbuild:
Bore 1191' and trench 82' to place conduit and fiber cable
Place 1478' of aerial fiber cable
Place 14 pedestals/cabinets/vaults
Total Outstanding Activity Conditions - 9
| Date | Name |
|---|---|
| 08/20/2026 | Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvement and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 08/20/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 08/20/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
| 08/20/2026 | Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. |
| 08/20/2026 | PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 09/24/2026 | All excavations shall be secured for safety at the end of each shift. If pedestrian access cannot be maintained, a temporary protected pedestrian route shall be provided. All open trenches shall be protected by Type II barricades with Type A flashers and surrounded by a barrier fence. Trenches deeper than 4 feet shall be surrounded by chain-link fence. Excavations may need to be covered with steel plates or other approved materials at the end of each shift. |
| 09/24/2026 | Lane and street closures shall be permitted only during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four-hour lane closures are not permitted unless specifically approved by the City. Traffic control devices shall not be stored in a bike lane or sidewalk. |
| 09/24/2026 | S Pacheco Av and Teton St are subject to a pavement moratorium. Any disturbance of existing asphalt will require pavement restoration in accordance with the current City of Tucson Public Utility Administrative Manual. A 2-inch mill and overlay covering one-half the width of the roadway shall be required. The final pavement restoration limits shall be confirmed by the ROW inspector at the preconstruction meeting. |
| 09/24/2026 | The contractor shall not block driveways or restrict resident access without prior notification and shall coordinate directly with affected property owners as necessary. |