Permit Details

Status:
Needs Resubmittal
Type:
Right-of-Way (ROW) - Utility
Address NEW:
621 E DRACHMAN ST
Apply Date:
08/04/2026
Applicant:
Robert Reynolds - National Barricade
Description:
8X8 BELL HOLE IN CONCRETE TO REPLACE GAS LINE. MAIN RUNS UNDER CURB AND SIDEWALK

Permit Reviews

Permit Number - TR-UTL-0826-01288
Permit Status: Needs resubmittal
Permit Description: 8X8 BELL HOLE IN CONCRETE TO REPLACE GAS LINE. MAIN RUNS UNDER CURB AND SIDEWALK
Start Date Submittal Complete Date Status  
08/14/2026 RIGHT-OF-WAY REVIEW v.3 08/20/2026 REQUIRES RESUBMIT Review Details
08/13/2026 RIGHT-OF-WAY REVIEW v.2 08/13/2026 REQUIRES RESUBMIT Review Details
08/04/2026 RIGHT-OF-WAY REVIEW v.1 08/05/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0826-01288
Permit Status: Needs resubmittal
Permit Description: 8X8 BELL HOLE IN CONCRETE TO REPLACE GAS LINE. MAIN RUNS UNDER CURB AND SIDEWALK
Total Outstanding Activity Conditions - 5
Date Name
08/04/2026 **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14
08/04/2026 Traffic Control set-up approved between 7AM - 5PM
08/04/2026 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
08/20/2026 Excavation - All excavations shall be secured for safety at the end of each shift. All open trenches shall be protected by Type II barricades with Type A flashers and surrounded by a barrier fence. Trenches deeper than 4 feet must be surrounded by chain-link fence. Excavations may need to be covered with steel plates or other approved materials at the end of each shift
08/20/2026 Neighborhood work - The contractor shall not block driveways or restrict resident access without prior notification and shall coordinate directly with affected property owners as necessary