Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
1509 E HELEN ST
Address NEW:
1509 E HELEN ST
Apply Date:
07/28/2026
Applicant:
Adrien Pineda
Description:
ARIZONA PIPELINE WILL NEED TO EXCAVATE (1)10'X2' IN THE DIRT ROW IN ORDER TO REPLACE THE GAS SERVICE FOR 1509 E HELEN ST

Permit Reviews

Permit Number - TR-UTL-0726-01250
Permit Status: Inspections
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE (1)10'X2' IN THE DIRT ROW IN ORDER TO REPLACE THE GAS SERVICE FOR 1509 E HELEN ST
Start Date Submittal Complete Date Status  
07/28/2026 RIGHT-OF-WAY REVIEW v.1 08/12/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0726-01250
Permit Status: Inspections
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE (1)10'X2' IN THE DIRT ROW IN ORDER TO REPLACE THE GAS SERVICE FOR 1509 E HELEN ST
Total Outstanding Activity Conditions - 7
Date Name
07/29/2026 Notify in writing at least 5 working days before work begins, any businesses, residences and public transit routes affected by your temporary traffic control. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.
07/29/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
07/29/2026 Traffic Control set-up approved between 7AM - 5PM
08/12/2026 Field Note: UA starts back Aug 24th. Closure Modification maybe required for Safe Access Accommodations.
08/12/2026 Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk - The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain all temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety
08/12/2026 Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14
08/12/2026 Private Property Driveways and private property shall NOT be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property.

Completed Inspections

Permit Status: Inspections
Permit Number: TR-UTL-0726-01250
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE (1)10'X2' IN THE DIRT ROW IN ORDER TO REPLACE THE GAS SERVICE FOR 1509 E HELEN ST
Total Completed Inspections - 1
Date Description Inspector Results Comments
08/18/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
1509 E HELEN ST TCP_V1.PDF DOCUMENTS VIEW
1509 E HELEN ST_V1.PDF DOCUMENTS VIEW