Permit: TR-UTL-0724-01347
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
5445 E 29TH ST
Address NEW:
5445 E 29TH ST
Apply Date:
07/19/2024
Applicant:
Bobby Akhter
Description:
Continuation of permit - TR-UTL-0324-00560 (Active Work) - 5445 E 29th St to NW corner of E 29th St & S Craycroft Rd. Bore 448' of 3-1.25" conduits, place 2 TCA hand holes to access aerial cable, Pull fiber.
Permit Reviews
Permit Number - TR-UTL-0724-01347
Permit Status: Complete
Permit Description: Continuation of permit - TR-UTL-0324-00560 (Active Work) - 5445 E 29th St to NW corner of E 29th St & S Craycroft Rd. Bore 448' of 3-1.25" conduits, place 2 TCA hand holes to access aerial cable, Pull fiber.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/22/2024 | RIGHT-OF-WAY REVIEW v.1 | 07/24/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0724-01347
Permit Status: Complete
Permit Description: Continuation of permit - TR-UTL-0324-00560 (Active Work) - 5445 E 29th St to NW corner of E 29th St & S Craycroft Rd. Bore 448' of 3-1.25" conduits, place 2 TCA hand holes to access aerial cable, Pull fiber.
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 07/22/2024 | BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. |
| 07/22/2024 | Traffic control set-up approved between 9AM - 3:30PM |
| 07/22/2024 | Pavement Patch type Shall Be in conformance to the current edition of the City of Tucson Public Utility Administrative Manual. |
| 07/22/2024 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0724-01347
Permit Description: Continuation of permit - TR-UTL-0324-00560 (Active Work) - 5445 E 29th St to NW corner of E 29th St & S Craycroft Rd. Bore 448' of 3-1.25" conduits, place 2 TCA hand holes to access aerial cable, Pull fiber.
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2024 | TRSP - ROW - Barricade - Setup/Routine | Passed | work already completed and barricade takedown completed | |
| 10/24/2024 | TRSP - ROW - Paving - Subgrade/removal/placement | Passed | no paving needed for project, all work done behind curb | |
| 10/24/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
| 10/24/2024 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 10/24/2024 | TRSP - ROW - Final | Passed |