Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
In Review
Type:
Right-of-Way (ROW) - Utility
Apply Date:
06/29/2026
Applicant:
Garcia David
Description:
MMR Fiber - SEGMENT 1 (Plan Phase 1) - This job (2)2" AND (4)7-WAY HDPE CONDUITS ALONG N Silverbell Rd. METHOD OF CONSTRUCTION TO BE DIRECTIONAL BORING AND/OR DIGGING/TRENCHING DEPENDING ON AREA AND ENGINEERING DRAWINGS. POSSIBLE PITS AND PLACING HANDHOLES. FIBER CABLE TO BE PLACED IN CONDUIT LOOPING INTO HANDHOLE. (DTM Note-- Refer to Attachments for Related Permit from Contractor)

Permit Reviews

Permit Number - TR-UTL-0626-01067
Permit Status: In review
Permit Description: MMR Fiber - SEGMENT 1 (Plan Phase 1) - This job (2)2" AND (4)7-WAY HDPE CONDUITS ALONG N Silverbell Rd. METHOD OF CONSTRUCTION TO BE DIRECTIONAL BORING AND/OR DIGGING/TRENCHING DEPENDING ON AREA AND ENGINEERING DRAWINGS. POSSIBLE PITS AND PLACING HANDHOLES. FIBER CABLE TO BE PLACED IN CONDUIT LOOPING INTO HANDHOLE. (DTM Note-- Refer to Attachments for Related Permit from Contractor)
Start Date Submittal Complete Date Status  
07/28/2026 RIGHT-OF-WAY REVIEW v.5 N/A IN REVIEW Review Details
07/07/2026 RIGHT-OF-WAY REVIEW v.2 N/A REQUIRES RESUBMIT Review Details
07/16/2026 RIGHT-OF-WAY REVIEW v.4 07/20/2026 REQUIRES RESUBMIT Review Details
06/29/2026 RIGHT-OF-WAY REVIEW v.1 N/A REQUIRES RESUBMIT Review Details
07/09/2026 RIGHT-OF-WAY REVIEW v.3 07/13/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0626-01067
Permit Status: In review
Permit Description: MMR Fiber - SEGMENT 1 (Plan Phase 1) - This job (2)2" AND (4)7-WAY HDPE CONDUITS ALONG N Silverbell Rd. METHOD OF CONSTRUCTION TO BE DIRECTIONAL BORING AND/OR DIGGING/TRENCHING DEPENDING ON AREA AND ENGINEERING DRAWINGS. POSSIBLE PITS AND PLACING HANDHOLES. FIBER CABLE TO BE PLACED IN CONDUIT LOOPING INTO HANDHOLE. (DTM Note-- Refer to Attachments for Related Permit from Contractor)
Total Outstanding Activity Conditions - 7
Date Name
07/09/2026 ADOT permits will be required for work in and Traffic Control within ADOT ROW
07/09/2026 This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to the Historic Preservation Office, City of Tucson, PO BOX 27210, Tucson AZ 85726...***Please contact Historic Preservation Office at PDSDHistoric@tucsonaz.gov.
07/09/2026 Approved for Work within City of Tucson Right of Way Only. Pima Couty permits will be required for work in and Traffic Control within Pima ROW
07/09/2026 Traffic control set-up approved between 9AM - 3:30PM
07/09/2026 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
07/09/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
07/09/2026 PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.