Permit: TR-UTL-0626-01050
Permit Details
Status:
Issued
Type:
Right-of-Way (ROW) - Utility
Address:
1725 E BILBY RD
Address NEW:
1725 E BILBY RD
Apply Date:
06/25/2026
Applicant:
Ilana Galluzzo
Description:
APPROVED TO SUBMIT FOR REGULAR ROW PERMIT PER GLORIA SALMERON - FRANCHISE PROJECT TO INSTALL NEW GAS MAIN ALONG E BILBY RD THROUGH A COMBINATION OF TRENCHING AND BORING. ESTIMATING APPROX 5,350' IN PAVEMENT AND APPROX 1,993' IN DIRT 07/30/26- Revision commentary page was send asking for change of hours.
Permit Reviews
Permit Number - TR-UTL-0626-01050
Permit Status: Issued
Permit Description: APPROVED TO SUBMIT FOR REGULAR ROW PERMIT PER GLORIA SALMERON - FRANCHISE PROJECT TO INSTALL NEW GAS MAIN ALONG E BILBY RD THROUGH A COMBINATION OF TRENCHING AND BORING. ESTIMATING APPROX 5,350' IN PAVEMENT AND APPROX 1,993' IN DIRT
07/30/26- Revision commentary page was send asking for change of hours.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/10/2026 | RIGHT-OF-WAY REVIEW v.3 | 07/10/2026 | APPROVED |
| 06/25/2026 | RIGHT-OF-WAY REVIEW v.1 | 06/25/2026 | REQUIRES RESUBMIT |
| 07/07/2026 | RIGHT-OF-WAY REVIEW v.2 | 07/10/2026 | REQUIRES RESUBMIT |
| 07/28/2026 | RIGHT-OF-WAY REVIEW REVISION v.1 | 07/31/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0626-01050
Permit Status: Issued
Permit Description: APPROVED TO SUBMIT FOR REGULAR ROW PERMIT PER GLORIA SALMERON - FRANCHISE PROJECT TO INSTALL NEW GAS MAIN ALONG E BILBY RD THROUGH A COMBINATION OF TRENCHING AND BORING. ESTIMATING APPROX 5,350' IN PAVEMENT AND APPROX 1,993' IN DIRT
07/30/26- Revision commentary page was send asking for change of hours.
Total Outstanding Activity Conditions - 10
| Date | Name |
|---|---|
| 06/25/2026 | BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. |
| 06/25/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 06/25/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
| 06/25/2026 | Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. |
| 06/25/2026 | PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 07/10/2026 | BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION WITH jose.garcia@tucsonaz.gov.. Due to the presence of a bus stop in the area, the contractor is required to contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 no less than 48 business hours before beginning work to coordinate impacts. |
| 07/10/2026 | Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk - The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain all temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 07/10/2026 | Private Property Driveways and private property shall NOT be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property |
| 07/28/2026 | Your project work requires that you contact the Sunnyside Unified School District to alert them and coordinate work as needed in school zones. |
| 07/31/2026 | The following extended traffic control set-up times were approved: Approved for 6:30am - 5:00 pm |
Completed Inspections
Permit Status: Issued
Permit Number: TR-UTL-0626-01050
Permit Description: APPROVED TO SUBMIT FOR REGULAR ROW PERMIT PER GLORIA SALMERON - FRANCHISE PROJECT TO INSTALL NEW GAS MAIN ALONG E BILBY RD THROUGH A COMBINATION OF TRENCHING AND BORING. ESTIMATING APPROX 5,350' IN PAVEMENT AND APPROX 1,993' IN DIRT
07/30/26- Revision commentary page was send asking for change of hours.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 08/10/2026 | TRSP - ROW - Barricade - Setup/Routine | Passed |