Permit: TR-UTL-0626-00936
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
2776 N WINSTEL BL
Address NEW:
2776 N WINSTEL BL
Apply Date:
06/03/2026
Applicant:
Kristine Schwartz
Description:
SWG crews will need to repair grade 3 leak on the curb and in the dirt, will need (1) 5x5 bellhole approx. 36'' deep.
Permit Reviews
Permit Number - TR-UTL-0626-00936
Permit Status: Complete
Permit Description: SWG crews will need to repair grade 3 leak on the curb and in the dirt, will need (1) 5x5 bellhole approx. 36'' deep.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/10/2026 | RIGHT-OF-WAY REVIEW v.2 | N/A | APPROVED |
| 06/04/2026 | RIGHT-OF-WAY REVIEW v.1 | 06/08/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-0626-00936
Permit Status: Complete
Permit Description: SWG crews will need to repair grade 3 leak on the curb and in the dirt, will need (1) 5x5 bellhole approx. 36'' deep.
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 06/08/2026 | **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 06/08/2026 | PAVEMENT MORATORIUM: ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 25’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. |
| 06/08/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 06/23/2026 | All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 06/23/2026 | Neighborhood work - The contractor shall not block driveways or restrict resident access without prior notification and shall coordinate directly with affected property owners as necessary |
| 06/23/2026 | Pavement Restoration - The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain all temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period |
| 06/23/2026 | Traffic Control Devices - Lane closures and street closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TR-UTL-0626-00936
Permite Description: SWG crews will need to repair grade 3 leak on the curb and in the dirt, will need (1) 5x5 bellhole approx. 36'' deep.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2026 | TRSP - ROW - Barricade - Setup/Routine | N/A | Partial Pass |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0626-00936
Permit Description: SWG crews will need to repair grade 3 leak on the curb and in the dirt, will need (1) 5x5 bellhole approx. 36'' deep.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 08/20/2026 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 08/20/2026 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 08/20/2026 | TRSP - ROW - Final | Passed |