Permit Details

Status:
Approved
Type:
Right-of-Way (ROW) - Utility
Address NEW:
3570 N CRAYCROFT RD
Apply Date:
06/01/2026
Applicant:
Brittany West
Description:
Tie in at existing fiber case. Bore 270' of 2" conduit at a depth of 3', run 270' of 48ct fiber. Place a new vault. Bore 200' of 2" conduit at a depth of 3', run 200' of 48ct fiber. Place a new vault. Bore 220' of 2" conduit at a depth of 3', run 220' of 48ct fiber. Place a new vault. Bore 110' of 2" conduit at a depth of 3', run 110' of 48ct fiber. Place a new lockbox.

Permit Reviews

Permit Number - TR-UTL-0626-00913
Permit Status: Approved
Permit Description: Tie in at existing fiber case. Bore 270' of 2" conduit at a depth of 3', run 270' of 48ct fiber. Place a new vault. Bore 200' of 2" conduit at a depth of 3', run 200' of 48ct fiber. Place a new vault. Bore 220' of 2" conduit at a depth of 3', run 220' of 48ct fiber. Place a new vault. Bore 110' of 2" conduit at a depth of 3', run 110' of 48ct fiber. Place a new lockbox.
Start Date Submittal Complete Date Status  
06/01/2026 RIGHT-OF-WAY REVIEW v.1 06/08/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0626-00913
Permit Status: Approved
Permit Description: Tie in at existing fiber case. Bore 270' of 2" conduit at a depth of 3', run 270' of 48ct fiber. Place a new vault. Bore 200' of 2" conduit at a depth of 3', run 200' of 48ct fiber. Place a new vault. Bore 220' of 2" conduit at a depth of 3', run 220' of 48ct fiber. Place a new vault. Bore 110' of 2" conduit at a depth of 3', run 110' of 48ct fiber. Place a new lockbox.
Total Outstanding Activity Conditions - 4
Date Name
06/08/2026 **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14
06/08/2026 Pedestrian Access – Continuous ADA-compliant pedestrian access shall be maintained at all times. If sidewalks are closed, an approved temporary pedestrian access route shall be provided in accordance with the Manual on Uniform Traffic Control Devices.
06/08/2026 Traffic Control Devices - Lane closures and street closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk.
06/08/2026 Traffic control set-up approved between 9AM - 3:30PM