Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-UTL-0625-00983
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
1147 N BEVERLY AV
Address NEW:
1147 N BEVERLY AV
Apply Date:
06/19/2025
Applicant:
Chelsey Bolinger
Description:
P.099104 (KAHNA) - BORE 202’ & TRENCH 67’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 2,056’ OF AERIAL FIBER CABLE. 8/18/25 REVISION: BORE 202’ & TRENCH 64’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 3,851’ OF AERIAL FIBER CABLE.
Permit Reviews
Permit Number - TR-UTL-0625-00983
Permit Status: Complete
Permit Description: P.099104 (KAHNA) - BORE 202’ & TRENCH 67’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 2,056’ OF AERIAL FIBER CABLE.
8/18/25 REVISION: BORE 202’ & TRENCH 64’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 3,851’ OF AERIAL FIBER CABLE.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/18/2025 | RIGHT-OF-WAY REVIEW REVISION v.1 | 08/18/2025 | APPROVED |
| 06/21/2025 | RIGHT-OF-WAY REVIEW v.1 | 06/24/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0625-00983
Permit Status: Complete
Permit Description: P.099104 (KAHNA) - BORE 202’ & TRENCH 67’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 2,056’ OF AERIAL FIBER CABLE.
8/18/25 REVISION: BORE 202’ & TRENCH 64’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 3,851’ OF AERIAL FIBER CABLE.
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 06/23/2025 | Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 06/23/2025 | ROW Permit is only allowed for work within City of Tucson Right of Way. |
| 06/23/2025 | Your project work requires that you contact City of Tucson Environmental Services Department (520-791-3171) at least 24 hours prior to closing any street or alley. |
| 06/23/2025 | Traffic control set-up approved between 9AM - 3:30PM |
| 06/23/2025 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
| 06/24/2025 | Message boards to be placed 5 days in advance of Wire Crossing, on all arterial road crossing, and to be performed during off peak hours |
| 08/18/2025 | Private Property Driveways and private property shall NOT be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0625-00983
Permit Description: P.099104 (KAHNA) - BORE 202’ & TRENCH 67’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 2,056’ OF AERIAL FIBER CABLE.
8/18/25 REVISION: BORE 202’ & TRENCH 64’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (3) HANDHOLES & PEDESTALS. OVERLASH 3,851’ OF AERIAL FIBER CABLE.
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 10/14/2025 | TRSP - ROW - Barricade Takedown | Passed | ||
| 10/14/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 10/14/2025 | TRSP - ROW - AERIAL INSTALLATION | Passed | ||
| 10/14/2025 | TRSP - ROW - Final | Passed |