Permit: TR-UTL-0625-00914
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
3829 E 4TH ST
Address NEW:
3829 E 4TH ST
Apply Date:
06/06/2025
Applicant:
Blair Montello
Description:
P.099168 (KAHNA) - BORE 859’ & TRENCH 102’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (13) HANDHOLES & PEDESTALS. OVERLASH 1,042’ OF AERIAL FIBER CABLE. 9/3/25- RENEWAL FOR 60 DAYS AS OF 9/23/25
Permit Reviews
Permit Number - TR-UTL-0625-00914
Permit Status: Complete
Permit Description: P.099168 (KAHNA) - BORE 859’ & TRENCH 102’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (13) HANDHOLES & PEDESTALS. OVERLASH 1,042’ OF AERIAL FIBER CABLE.
9/3/25- RENEWAL FOR 60 DAYS AS OF 9/23/25
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/06/2025 | RIGHT-OF-WAY REVIEW v.1 | 06/09/2025 | APPROVED |
| 08/11/2025 | RIGHT-OF-WAY REVIEW REVISION v.1 | 08/11/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0625-00914
Permit Status: Complete
Permit Description: P.099168 (KAHNA) - BORE 859’ & TRENCH 102’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (13) HANDHOLES & PEDESTALS. OVERLASH 1,042’ OF AERIAL FIBER CABLE.
9/3/25- RENEWAL FOR 60 DAYS AS OF 9/23/25
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 06/06/2025 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 06/06/2025 | Traffic control set-up approved between 9AM - 3:30PM |
| 06/09/2025 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST MARKED ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO MARKED ADA RAMPS AND CROSSING ACCESSABLE WITHIN 660' OF SIDEWALK CLOSURE. ACCESSABLE. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. |
| 06/09/2025 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0625-00914
Permit Description: P.099168 (KAHNA) - BORE 859’ & TRENCH 102’ TO PLACE CTL CONDUIT & FIBER CABLE. PLACE (1) FSAI CABINET, (13) HANDHOLES & PEDESTALS. OVERLASH 1,042’ OF AERIAL FIBER CABLE.
9/3/25- RENEWAL FOR 60 DAYS AS OF 9/23/25
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/31/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 10/01/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 10/01/2025 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 10/01/2025 | TRSP - ROW - Final | Passed |