Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
761 N BONANZA AV
Address NEW:
761 N BONANZA AV
Apply Date:
06/02/2023
Applicant:
Description:
323002 Site 3 - Install Approximately 142 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 8373-05-2 per PCRWRD standard detail 212

Permit Reviews

Permit Number - TR-UTL-0623-01701
Permit Status: Complete
Permit Description: 323002 Site 3 - Install Approximately 142 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 8373-05-2 per PCRWRD standard detail 212
Start Date Submittal Complete Date Status  
06/02/2023 RIGHT-OF-WAY REVIEW v.1 06/05/2023 APPROVED Review Details

Conditions

Permit Number - TR-UTL-0623-01701
Permit Status: Complete
Permit Description: 323002 Site 3 - Install Approximately 142 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 8373-05-2 per PCRWRD standard detail 212
Date Description Comments
06/02/2023 PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
06/02/2023 Traffic control set-up approved between 9AM - 3:30PM

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-0623-01701
Permit Description: 323002 Site 3 - Install Approximately 142 LF of 12" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars and manhole bench rehabilitation will be completed on MH's 8373-05-2 per PCRWRD standard detail 212
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/17/2023 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
10/17/2023 TRSP - ROW - Final/Close-Out Passed
10/17/2023 TRSP - ROW - Recurring Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
3230X2 - SITE 3 FMP MAP (761 N BONANZA AVE)_V1.PDF DOCUMENTS VIEW
DB 67897 - PAGE 3 - 761 N. BANANZA AVE - BUMPOUTS - ALLEYS - 3230X2_V1.PDF DOCUMENTS VIEW