Permit: TR-UTL-0526-00818
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
618 W ROGER RD
Address NEW:
618 W ROGER RD
Apply Date:
05/12/2026
Applicant:
Kristine Schwartz
Description:
2 5x5 bellholes in dirt/blktop front for crews to repair gas facilities
Permit Reviews
Permit Number - TR-UTL-0526-00818
Permit Status: Complete
Permit Description: 2 5x5 bellholes in dirt/blktop front for crews to repair gas facilities
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/12/2026 | RIGHT-OF-WAY REVIEW v.1 | 05/14/2026 | REQUIRES RESUBMIT |
| 05/15/2026 | RIGHT-OF-WAY REVIEW v.2 | 05/19/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0526-00818
Permit Status: Complete
Permit Description: 2 5x5 bellholes in dirt/blktop front for crews to repair gas facilities
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 05/12/2026 | PAVEMENT MORATORIUM: ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 25’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. |
| 05/12/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 05/18/2026 | - The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain all temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 05/18/2026 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 05/18/2026 | Pre-Activity Meeting w/Inspections Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0526-00818
Permit Description: 2 5x5 bellholes in dirt/blktop front for crews to repair gas facilities
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | Jeremy Carrico, phone number: (520) 247-9604. call sw gas This is for a potential repair, investigating a damage sewer next to gas pipe. They're hoping the majority of the work is done under sidewalk and in the dirt if it gets into the road, they're going to notify me when they get out here. |
|
| 07/16/2026 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 07/15/2026 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 07/17/2026 | TRSP - ROW - Final | Passed | Yes all clear emergency Southwest gas repair and restoration of the driveway. Apron in peace complete |