Permit: TR-UTL-0526-00801
Permit Details
Status:
Issued
Type:
Right-of-Way (ROW) - Utility
Address:
1510 S MARMORA AV
Address NEW:
1510 S MARMORA AV
Apply Date:
05/11/2026
Applicant:
Cox Communications
Description:
PRJ315152-1 - Cox to trench 4' and bore 306' to install new CATV conduit for service repair order
Permit Reviews
Permit Number - TR-UTL-0526-00801
Permit Status: Issued
Permit Description: PRJ315152-1 - Cox to trench 4' and bore 306' to install new CATV conduit for service repair order
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/11/2026 | RIGHT-OF-WAY REVIEW v.1 | 05/14/2026 | REQUIRES RESUBMIT |
| 06/01/2026 | RIGHT-OF-WAY REVIEW v.2 | 06/01/2026 | VOID |
Outstanding Activity Conditions
Permit Number - TR-UTL-0526-00801
Permit Status: Issued
Permit Description: PRJ315152-1 - Cox to trench 4' and bore 306' to install new CATV conduit for service repair order
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 05/13/2026 | **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 05/13/2026 | Traffic Control set-up approved between 7AM - 5PM |
| 05/14/2026 | Excavation - All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 05/14/2026 | S Marmora Av is subject to a pavement moratorium. A 2-inch mill and overlay, covering one-half the width of the roadway, shall be required. The required pavement restoration treatment shall be confirmed by the ROW Inspector at the preconstruction meeting. |
| 05/14/2026 | The contractor shall not block driveways or restrict resident access without prior notification and shall coordinate directly with affected property owners as necessary |