Permit: TR-UTL-0525-00857
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
8050 E 22ND ST
Address NEW:
8050 E 22ND ST
Apply Date:
05/29/2025
Applicant:
Cox Communications
Description:
Cox to trench 8' and bore 192' to install conduit for system tie.
Permit Reviews
Permit Number - TR-UTL-0525-00857
Permit Status: Complete
Permit Description: Cox to trench 8' and bore 192' to install conduit for system tie.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2025 | RIGHT-OF-WAY REVIEW v.2 | 06/16/2025 | APPROVED |
| 05/29/2025 | RIGHT-OF-WAY REVIEW v.1 | 06/02/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-0525-00857
Permit Status: Complete
Permit Description: Cox to trench 8' and bore 192' to install conduit for system tie.
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 05/29/2025 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 05/29/2025 | Traffic control set-up approved between 9AM - 3:30PM |
| 06/13/2025 | BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. |
| 06/13/2025 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST MARKED ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO MARKED ADA RAMPS AND CROSSING ACCESSABLE WITHIN 660' OF SIDEWALK CLOSURE. ACCESSABLE. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. |
| 06/13/2025 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0525-00857
Permit Description: Cox to trench 8' and bore 192' to install conduit for system tie.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | Spoke with Francisco over the phone for the pre-activity meeting | |
| 06/27/2025 | TRSP - ROW - Barricade - Setup/Routine | Passed | Work is complete, but no traffic control set up inspection was ever requested | |
| 06/27/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | Work is complete | |
| 07/03/2025 | TRSP - ROW - Final | Passed | Work is complete |