Permit: TR-UTL-0326-00508
Permit Details
Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
758 E PASTIME RD
Address NEW:
758 E PASTIME RD
Apply Date:
03/11/2026
Applicant:
ANGEL MORALES
Description:
P.348377B BORE 276' AND TRENCH 35' TO PLACE CONDUIT AND FIBER CABLE PULL 278' OF FIBER CABLE THROUGH EXISTIND CONDUIT PLACE 2960' OF AERIAL FIBER CABLE PLACE 1 PEDESTAL
Permit Reviews
Permit Number - TR-UTL-0326-00508
Permit Status: Inspections
Permit Description: P.348377B
BORE 276' AND TRENCH 35' TO PLACE CONDUIT AND FIBER CABLE
PULL 278' OF FIBER CABLE THROUGH EXISTIND CONDUIT
PLACE 2960' OF AERIAL FIBER CABLE
PLACE 1 PEDESTAL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/12/2026 | RIGHT-OF-WAY REVIEW v.1 | 03/13/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0326-00508
Permit Status: Inspections
Permit Description: P.348377B
BORE 276' AND TRENCH 35' TO PLACE CONDUIT AND FIBER CABLE
PULL 278' OF FIBER CABLE THROUGH EXISTIND CONDUIT
PLACE 2960' OF AERIAL FIBER CABLE
PLACE 1 PEDESTAL
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 03/12/2026 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 03/12/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 03/13/2026 | All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 03/13/2026 | Continuous ADA-compliant pedestrian access shall be maintained at all times. If sidewalks are closed, an approved temporary pedestrian access route shall be provided in accordance with the Manual on Uniform Traffic Control Devices |
| 03/13/2026 | Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk. |
| 03/13/2026 | The contractor shall not block driveways or restrict resident access without prior notification and shall coordinate directly with affected property owners as necessary |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-UTL-0326-00508
Permite Description: P.348377B
BORE 276' AND TRENCH 35' TO PLACE CONDUIT AND FIBER CABLE
PULL 278' OF FIBER CABLE THROUGH EXISTIND CONDUIT
PLACE 2960' OF AERIAL FIBER CABLE
PLACE 1 PEDESTAL
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2026 | TRSP - ROW - Barricade - Setup/Routine | N/A | Re-inspection required | No work started on this permit there renewing today and will have a precon prior to starting |
| 06/30/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | N/A | Re-inspection required | No work started on this permit there renewing today and will have a precon prior to starting |
| 06/30/2026 | TRSP - ROW - Backfill - Placement/Compaction | N/A | Re-inspection required | No work started on this permit there renewing today and will have a precon prior to starting |
| 06/30/2026 | TRSP - ROW - Final | N/A | Re-inspection required | No work started on this permit there renewing today and will have a precon prior to starting |