Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address NEW:
3352 N ALVERNON WY
Apply Date:
03/03/2026
Applicant:
Brittany West
Description:
Overlash 1325' of 48ct fiber over 10 spans. Overlash 330' of 48ct fiber over 2 spans. Place 145' of new strand, place 145' of 48ct fiber over 1 span. Riser down and place new vault at base of pole. Bore 320' of 2" conduit at a depth of 3', run 320' of 48ct fiber. Place new vault. Place 1120' of new strand, place 1120' of 48ct fiber over 9 span. Place new vault. Place 110' of new strand, place 110' of 48ct fiber over 1 span. Riser down and bore 600' of 2" conduit at a depth of 3', run 600' of 48ct fiber. Place 2 new vaults.

Permit Reviews

Permit Number - TR-UTL-0326-00437
Permit Status: Complete
Permit Description: Overlash 1325' of 48ct fiber over 10 spans. Overlash 330' of 48ct fiber over 2 spans. Place 145' of new strand, place 145' of 48ct fiber over 1 span. Riser down and place new vault at base of pole. Bore 320' of 2" conduit at a depth of 3', run 320' of 48ct fiber. Place new vault. Place 1120' of new strand, place 1120' of 48ct fiber over 9 span. Place new vault. Place 110' of new strand, place 110' of 48ct fiber over 1 span. Riser down and bore 600' of 2" conduit at a depth of 3', run 600' of 48ct fiber. Place 2 new vaults.
Start Date Submittal Complete Date Status  
03/03/2026 RIGHT-OF-WAY REVIEW v.1 03/09/2026 REQUIRES RESUBMIT Review Details
03/11/2026 RIGHT-OF-WAY REVIEW v.2 03/13/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0326-00437
Permit Status: Complete
Permit Description: Overlash 1325' of 48ct fiber over 10 spans. Overlash 330' of 48ct fiber over 2 spans. Place 145' of new strand, place 145' of 48ct fiber over 1 span. Riser down and place new vault at base of pole. Bore 320' of 2" conduit at a depth of 3', run 320' of 48ct fiber. Place new vault. Place 1120' of new strand, place 1120' of 48ct fiber over 9 span. Place new vault. Place 110' of new strand, place 110' of 48ct fiber over 1 span. Riser down and bore 600' of 2" conduit at a depth of 3', run 600' of 48ct fiber. Place 2 new vaults.
Total Outstanding Activity Conditions - 6
Date Name
03/06/2026 Bus stop in the area, contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 at least 48-business hours prior to start of work for coordination.
03/06/2026 ROW Permit is only allowed for work within City of Tucson Right of Way.
03/06/2026 Approved for Work within City of Tucson Right of Way Only. Pima Couty permits will be required for work in and Traffic Control within Pima ROW
03/06/2026 Traffic control set-up approved between 9AM - 3:30PM
03/06/2026 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
03/06/2026 UNDER A PAVEMENT MORATORIUM, ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 25’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES.

Completed Inspections

Permit Status: Complete
Permit Number: TR-UTL-0326-00437
Permit Description: Overlash 1325' of 48ct fiber over 10 spans. Overlash 330' of 48ct fiber over 2 spans. Place 145' of new strand, place 145' of 48ct fiber over 1 span. Riser down and place new vault at base of pole. Bore 320' of 2" conduit at a depth of 3', run 320' of 48ct fiber. Place new vault. Place 1120' of new strand, place 1120' of 48ct fiber over 9 span. Place new vault. Place 110' of new strand, place 110' of 48ct fiber over 1 span. Riser down and bore 600' of 2" conduit at a depth of 3', run 600' of 48ct fiber. Place 2 new vaults.
Total Completed Inspections - 4
Date Description Inspector Results Comments
04/20/2026 TRSP - ROW - Barricade - Setup/Routine Passed
04/20/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
04/20/2026 TRSP - ROW - AERIAL INSTALLATION Passed
04/20/2026 TRSP - ROW - Final Passed