Permit: TR-UTL-0226-00375
Permit Details
Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
910 N SWAN RD
Address NEW:
910 N SWAN RD
Apply Date:
02/23/2026
Applicant:
Esteban Vega - Desert Barricades
Description:
WO T175222 - LINE CREWS REPLACING 40' WOOD POLE WITH A 45' STEEL POLE AS MAINTENANCE WORK
Permit Reviews
Permit Number - TR-UTL-0226-00375
Permit Status: Inspections
Permit Description: WO T175222 - LINE CREWS REPLACING 40' WOOD POLE WITH A 45' STEEL POLE AS MAINTENANCE WORK
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/03/2026 | RIGHT-OF-WAY REVIEW v.2 | 03/04/2026 | APPROVED |
| 02/24/2026 | RIGHT-OF-WAY REVIEW v.1 | 03/02/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-0226-00375
Permit Status: Inspections
Permit Description: WO T175222 - LINE CREWS REPLACING 40' WOOD POLE WITH A 45' STEEL POLE AS MAINTENANCE WORK
Total Outstanding Activity Conditions - 8
| Date | Name |
|---|---|
| 02/26/2026 | Bus stop in the area, contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 at least 48-business hours prior to start of work for coordination. |
| 02/26/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 02/26/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
| 03/04/2026 | Bike Lane Access and Accommodation- Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions Bike lane to be maintained within Traffic Control closure and Share may Pedestrian detour path with proper R9-6 Sign. |
| 03/04/2026 | Due to the presence of a bus stop in the area, the contractor is required to contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 no less than 48 business hours before beginning work to coordinate impacts |
| 03/04/2026 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 03/04/2026 | Pre-Activity Meeting w/Inspections Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 03/04/2026 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |
Completed Inspections
Permit Status: Inspections
Permit Number: TR-UTL-0226-00375
Permit Description: WO T175222 - LINE CREWS REPLACING 40' WOOD POLE WITH A 45' STEEL POLE AS MAINTENANCE WORK
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | Site is ready for work to begin. One single pole replacement with no impact to any sidewalks. Some traffic control is already on site for another project |