Permit: TR-UTL-0226-00275
Permit Details
Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
7040 E STRIKE EAGLE WY
Address NEW:
7040 E STRIKE EAGLE WY
Apply Date:
02/13/2026
Applicant:
ANGEL MORALES
Description:
P.092665C BORE 3931' AND TRENCH 16' TO PLACE CONDUIT AND FIBER CABLE PLACE 1240' OF AERIAL FIBER CABLE PLACE 18 PEDESTALS
Permit Reviews
Permit Number - TR-UTL-0226-00275
Permit Status: Inspections
Permit Description: P.092665C
BORE 3931' AND TRENCH 16' TO PLACE CONDUIT AND FIBER CABLE
PLACE 1240' OF AERIAL FIBER CABLE
PLACE 18 PEDESTALS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/13/2026 | RIGHT-OF-WAY REVIEW v.2 | 03/18/2026 | APPROVED |
| 02/13/2026 | RIGHT-OF-WAY REVIEW v.1 | 03/02/2026 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-UTL-0226-00275
Permit Status: Inspections
Permit Description: P.092665C
BORE 3931' AND TRENCH 16' TO PLACE CONDUIT AND FIBER CABLE
PLACE 1240' OF AERIAL FIBER CABLE
PLACE 18 PEDESTALS
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 02/13/2026 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 Bike Lane Access and Accommodation 1. Posted Speeds 30 Mph or Less – Less than 14 lane - Use of the R4-11 alone is acceptable and preferred over Share The Road sign - 2. Posted Speeds 30 Mph or less – greater than 14 lane - Use of Share The Road sign is preferred 3. Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions |
| 02/13/2026 | Traffic control set-up approved between 9AM - 3:30PM |
| 02/27/2026 | All excavations must be securely plated or backfilled at the end of each workday and during any period when the site is unattended. Plating shall be traffic-rated, flush with the surrounding surface, and properly secured to prevent movement and to maintain public safety |
| 02/27/2026 | Due to the presence of a bus stop in the area, the contractor is required to contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 no less than 48 business hours before beginning work to coordinate impacts |
| 03/18/2026 | Lane closures shall only be permitted during active work operations. At the end of each workday, the contractor shall remove all traffic control devices and reopen the roadway, bike lanes, and sidewalks to normal operation. Twenty-four (24) hour lane closures are not permitted unless specifically approved by the City. Traffic Control Devices shall not be stored in the bike lane or sidewalk. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-UTL-0226-00275
Permite Description: P.092665C
BORE 3931' AND TRENCH 16' TO PLACE CONDUIT AND FIBER CABLE
PLACE 1240' OF AERIAL FIBER CABLE
PLACE 18 PEDESTALS
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2026 | TRSP - ROW - Barricade - Setup/Routine | N/A | Not Ready | phone call with Skyler, job has not been assigned yet. Current permit set to expire this week, extension request has been submitted. |
| 06/16/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | N/A | Re-inspection required | phone call with Skyler, job has not been assigned yet. Current permit set to expire this week, extension request has been submitted. |
| 06/16/2026 | TRSP - ROW - Backfill - Placement/Compaction | N/A | Not Ready | phone call with Skyler, job has not been assigned yet. Current permit set to expire this week, extension request has been submitted. |
| 06/16/2026 | TRSP - ROW - Final | N/A | Not Ready | phone call with Skyler, job has not been assigned yet. Current permit set to expire this week, extension request has been submitted. |