Permit: TR-UTL-0226-00259
Permit Details
Status:
Inspections
Type:
Right-of-Way (ROW) - Utility
Address:
10487 E BRIDGESTONE PL
Address NEW:
10487 E BRIDGESTONE PL
Apply Date:
02/11/2026
Applicant:
Kristine Schwartz
Description:
2 5x5 bellholes in blktop front for crews to repair gas facilities
Permit Reviews
Permit Number - TR-UTL-0226-00259
Permit Status: Inspections
Permit Description: 2 5x5 bellholes in blktop front for crews to repair gas facilities
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/12/2026 | RIGHT-OF-WAY REVIEW v.1 | 02/12/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0226-00259
Permit Status: Inspections
Permit Description: 2 5x5 bellholes in blktop front for crews to repair gas facilities
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 02/12/2026 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 02/12/2026 | Emergency – After the fact permit – a TCP was not provided due to the nature of the work. Any legal questions related to this work shall be directed to Southwest Gas to address since DTM did not have an opportunity to review, approve or inspect work. |
| 02/12/2026 | PAVEMENT MORATORIUM: ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 25’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. |
| 02/12/2026 | Traffic Control set-up approved between 7AM - 5PM |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-UTL-0226-00259
Permite Description: 2 5x5 bellholes in blktop front for crews to repair gas facilities
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2026 | TRSP - ROW - Final | N/A | Re-inspection required | temporary patches in place, permanent patch between multiple cuts needed for final approval |