Permit: TR-UTL-0224-00228
Permit Details
Apply Date:
02/05/2024
Applicant:
Cox Communications
Description:
Cox to aerial overlash 597', pull 550' of fiber through existing conduit and bore 243' to install CATV conduit for system tie.
Permit Reviews
Permit Number - TR-UTL-0224-00228
Permit Status: Issued
Permit Description: Cox to aerial overlash 597', pull 550' of fiber through existing conduit and bore 243' to install CATV conduit for system tie.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/05/2024 | RIGHT-OF-WAY REVIEW v.1 | 02/07/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0224-00228
Permit Status: Issued
Permit Description: Cox to aerial overlash 597', pull 550' of fiber through existing conduit and bore 243' to install CATV conduit for system tie.
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
02/05/2024 | Traffic control set-up approved between 9AM - 3:30PM |
02/05/2024 | (411 Work Area Contact Nick Germanos at Nick.Germanos@tucsonaz.gov, Prior to Start of Work.) OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. |
02/05/2024 | Pavement Patch type Shall Be in conformance to the current edition of the City of Tucson Public Utility Administrative Manual. (Note 411 Pavement Restoration Area.) |
02/05/2024 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TR-UTL-0224-00228
Permite Description: Cox to aerial overlash 597', pull 550' of fiber through existing conduit and bore 243' to install CATV conduit for system tie.
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/28/2024 | TRSP - ROW - Backfill - Placement/Compaction | N/A | Re-inspection required | no compaction tests given. |
05/28/2024 | TRSP - ROW - Concrete - Acceptance (Post-Pour) | N/A | Re-inspection required | no concrete completed or required. |
05/28/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | N/A | Re-inspection required | no concrete required |
Completed Inspections
Permit Status: Issued
Permit Number: TR-UTL-0224-00228
Permit Description: Cox to aerial overlash 597', pull 550' of fiber through existing conduit and bore 243' to install CATV conduit for system tie.
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | Did a precon with Truenet. Most of the work will be on shoulder and Ariel | |
03/05/2024 | TRSP - ROW - AERIAL INSTALLATION | Passed | ||
03/04/2024 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
05/28/2024 | TRSP - ROW - SWBMP | Passed | ||
05/28/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
05/28/2024 | TRSP - ROW - Final/Close-Out | Passed |