Permit: TR-UTL-0125-00188
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
7602 E EDISON ST
Address NEW:
7602 E EDISON ST
Apply Date:
01/29/2025
Applicant:
Andrea Charles
Description:
We will be boring in a new 2" conduit with 48ct fiber along the shoulder of N Grady Ave and down the easement to N Camino Pio Decimo for a total distance of 1,800'. We will traffic control set up for the duration of the work.
Permit Reviews
Permit Number - TR-UTL-0125-00188
Permit Status: Complete
Permit Description: We will be boring in a new 2" conduit with 48ct fiber along the shoulder of N Grady Ave and down the easement to N Camino Pio Decimo for a total distance of 1,800'. We will traffic control set up for the duration of the work.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2025 | RIGHT-OF-WAY REVIEW v.1 | 02/03/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0125-00188
Permit Status: Complete
Permit Description: We will be boring in a new 2" conduit with 48ct fiber along the shoulder of N Grady Ave and down the easement to N Camino Pio Decimo for a total distance of 1,800'. We will traffic control set up for the duration of the work.
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 01/31/2025 | Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 01/31/2025 | Traffic Control set-up approved between 7AM - 5PM |
| 01/31/2025 | NOTE: WORK IS BEHIND 7602 E EDISON ST - ADDRESS ON PERMIT IS FOR PERMITTING PURPOSES ONLY. |
| 02/03/2025 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
| 02/03/2025 | Private Property Driveways and private property shall NOT be utilized without the owner’s consent. It is the contractor’s responsibility to negotiate use of private property. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0125-00188
Permit Description: We will be boring in a new 2" conduit with 48ct fiber along the shoulder of N Grady Ave and down the easement to N Camino Pio Decimo for a total distance of 1,800'. We will traffic control set up for the duration of the work.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | met with Rich and Miguel on site, white lining to be red drawn to reflect permit map. Traffic control plan to be re-uploaded for legibility, completed 811 ticket will determine start date. | |
| 04/11/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 04/11/2025 | TRSP - ROW - Final | Passed |