ARIZONA PIPELINE WILL NEED TO EXCAVATE 1 6'X2' TRENCH AND 1 4'X4' BELL HOLE IN ASPHALT ROW IN ORDER TO REPLACE GAS SERVICE

Permit Reviews

Permit Number - TR-UTL-0125-00095
Permit Status: Inspections
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE 1 6'X2' TRENCH AND 1 4'X4' BELL HOLE IN ASPHALT ROW IN ORDER TO REPLACE GAS SERVICE
Start Date Submittal Complete Date Status  
01/23/2025 RIGHT-OF-WAY REVIEW v.2 01/23/2025 APPROVED Review Details
01/16/2025 RIGHT-OF-WAY REVIEW v.1 01/21/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-UTL-0125-00095
Permit Status: Inspections
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE 1 6'X2' TRENCH AND 1 4'X4' BELL HOLE IN ASPHALT ROW IN ORDER TO REPLACE GAS SERVICE
Total Outstanding Activity Conditions - 4
Date Name
01/21/2025 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
01/21/2025 Traffic Control set-up approved between 7AM - 5PM
01/23/2025 PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL.
01/23/2025 Pre-Activity Meeting  Pre- activity meeting to be held 72 hrs in advance of work start with inspections..  PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.

Completed Inspections

Permit Status: Inspections
Permit Number: TR-UTL-0125-00095
Permit Description: ARIZONA PIPELINE WILL NEED TO EXCAVATE 1 6'X2' TRENCH AND 1 4'X4' BELL HOLE IN ASPHALT ROW IN ORDER TO REPLACE GAS SERVICE
Total Completed Inspections - 4
Date Description Inspector Results Comments
01/28/2025 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
02/05/2025 TRSP - ROW - Barricade - Setup/Routine Passed
02/25/2025 TRSP - ROW - Backfill - Placement/Compaction Passed
11/14/2025 TRSP - ROW - Final Passed