Permit: TR-UTL-0124-00045
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW) - Utility
Address:
449 W 38TH ST
Address NEW:
449 W 38TH ST
Apply Date:
01/08/2024
Applicant:
Desert Barricades LLC
Description:
TEP WO 6346126 - 8 Pole Replacements. Transfer (1) Secondary Risers. Install (2) Secondary Riser & Pedestal. Replace Primary Riser & Break into existing conduit - TEP CONTACT IS ADAM SHAW/(520) 334-9568.
Permit Reviews
Permit Number - TR-UTL-0124-00045
Permit Status: Complete
Permit Description: TEP WO 6346126 - 8 Pole Replacements. Transfer (1) Secondary Risers. Install (2) Secondary Riser & Pedestal. Replace Primary Riser & Break into existing conduit - TEP CONTACT IS ADAM SHAW/(520) 334-9568.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/09/2024 | RIGHT-OF-WAY REVIEW v.1 | 01/18/2024 | APPROVED |
| 02/08/2024 | RIGHT-OF-WAY REVIEW v.1 | 02/09/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-UTL-0124-00045
Permit Status: Complete
Permit Description: TEP WO 6346126 - 8 Pole Replacements. Transfer (1) Secondary Risers. Install (2) Secondary Riser & Pedestal. Replace Primary Riser & Break into existing conduit - TEP CONTACT IS ADAM SHAW/(520) 334-9568.
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 01/09/2024 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 01/09/2024 | Traffic Control set-up approved between 7AM - 5PM |
| 01/18/2024 |
Outstanding Inspections
Permit Status: Complete
Permit Number: TR-UTL-0124-00045
Permite Description: TEP WO 6346126 - 8 Pole Replacements. Transfer (1) Secondary Risers. Install (2) Secondary Riser & Pedestal. Replace Primary Riser & Break into existing conduit - TEP CONTACT IS ADAM SHAW/(520) 334-9568.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2024 | TRSP - ROW - SITE INSPECTION | N/A | Partial Pass |
Completed Inspections
Permit Status: Complete
Permit Number: TR-UTL-0124-00045
Permit Description: TEP WO 6346126 - 8 Pole Replacements. Transfer (1) Secondary Risers. Install (2) Secondary Riser & Pedestal. Replace Primary Riser & Break into existing conduit - TEP CONTACT IS ADAM SHAW/(520) 334-9568.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 05/03/2024 | TRSP - ROW - Final/Close-Out | Passed |