Permit: TR-SWF-0924-00013
Permit Details
Apply Date:
09/20/2024
Applicant:
Nick Gasior
Description:
SOW for TUC30_012 Remove existing antenna and RRHs Install (1) canister antenna on new mount Install (1) RRH unit inside RRH cabinet Install (1) RRH cabinet on concrete slab Install new 4” conduit for fiber from hand holes to pole – trench approx. 14’-0” Install new 4” conduit for power from cabinet to meter – trench approx. 42’-0” Existing 2.5” conduit to be intercepted from small cell pole to Charles RRH cabinet Existing 4” conduit for coax (AT&T vault to pole) at 21’ w/1.25” innerduct at 55’-0” & (2) 35M fiber jumpers.
Permit Reviews
Permit Number - TR-SWF-0924-00013
Permit Status: Issued
Permit Description: SOW for TUC30_012
Remove existing antenna and RRHs
Install (1) canister antenna on new mount
Install (1) RRH unit inside RRH cabinet
Install (1) RRH cabinet on concrete slab
Install new 4” conduit for fiber from hand holes to pole – trench approx. 14’-0”
Install new 4” conduit for power from cabinet to meter – trench approx. 42’-0”
Existing 2.5” conduit to be intercepted from small cell pole to Charles RRH cabinet
Existing 4” conduit for coax (AT&T vault to pole) at 21’ w/1.25” innerduct at 55’-0” & (2) 35M fiber jumpers.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/19/2024 | SMALL WIRELESS FACILITIES REVIEW v.3 | 11/21/2024 | REQUIRES RESUBMIT |
09/23/2024 | SMALL WIRELESS FACILITIES REVIEW v.1 | 10/01/2024 | REQUIRES RESUBMIT |
12/09/2024 | SMALL WIRELESS FACILITIES REVIEW v.4 | 12/10/2024 | APPROVED |
11/15/2024 | SMALL WIRELESS FACILITIES REVIEW v.2 | 11/18/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-SWF-0924-00013
Permit Status: Issued
Permit Description: SOW for TUC30_012
Remove existing antenna and RRHs
Install (1) canister antenna on new mount
Install (1) RRH unit inside RRH cabinet
Install (1) RRH cabinet on concrete slab
Install new 4” conduit for fiber from hand holes to pole – trench approx. 14’-0”
Install new 4” conduit for power from cabinet to meter – trench approx. 42’-0”
Existing 2.5” conduit to be intercepted from small cell pole to Charles RRH cabinet
Existing 4” conduit for coax (AT&T vault to pole) at 21’ w/1.25” innerduct at 55’-0” & (2) 35M fiber jumpers.
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
12/09/2024 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO ADA RAMPS ACCESSABLE. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 |
12/09/2024 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
12/09/2024 | Traffic control set-up approved between 9AM - 3:30PM |
12/09/2024 | Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area. |