Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way Small Wireless
Address:
5732 S Tucson BL
Address NEW:
5732 S Tucson BL
Apply Date:
04/09/2025
Applicant:
Brad Lowe
Description:
SOW FOR TUC40_021 (14875201) Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (1) RRH unit inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 23’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Install new 1.5” conduit from existing pull box to new RRH cabinet – trench approx. 20’-10”. Install new 1.5” conduit from new RRH cabinet to existing pole – trench approx. 49’-8”.

Permit Reviews

Permit Number - TR-SWF-0425-00061
Permit Status: Complete
Permit Description: SOW FOR TUC40_021 (14875201) Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (1) RRH unit inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 23’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Install new 1.5” conduit from existing pull box to new RRH cabinet – trench approx. 20’-10”. Install new 1.5” conduit from new RRH cabinet to existing pole – trench approx. 49’-8”.
Start Date Submittal Complete Date Status  
05/30/2025 SMALL WIRELESS FACILITIES REVIEW v.2 06/02/2025 APPROVED Review Details
04/16/2025 SMALL WIRELESS FACILITIES REVIEW v.1 05/23/2025 REQUIRES RESUBMIT Review Details

Completed Inspections

Permit Status: Complete
Permit Number: TR-SWF-0425-00061
Permit Description: SOW FOR TUC40_021 (14875201) Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (1) RRH unit inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 23’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Install new 1.5” conduit from existing pull box to new RRH cabinet – trench approx. 20’-10”. Install new 1.5” conduit from new RRH cabinet to existing pole – trench approx. 49’-8”.
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/19/2025 TRSP - SWF - Preconstruction Meeting Passed
09/16/2025 TRSP - SWF - Recurring Passed
09/16/2025 TRSP - SWF - Miscellaneous/Unscheduled Passed
11/17/2025 TRSP - SWF - Final Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
14875201 TUC40_021 100 CDS - REV 0 04.09.25_V1.PDF DOCUMENTS VIEW
STATE 48 DEVELOPMENT -5750 S TUCSON BLVD - RIGHT LANE CL PLAN 3 - CRAN_RANM_TUC40_021 V2_V2.PDF DOCUMENTS VIEW