Permit: TR-SWF-0225-00045
Permit Details
Status:
Complete
Type:
Right-of-Way Small Wireless
Address:
4180 E CAMEO POINT DR
Address NEW:
4180 E CAMEO POINT DR
Apply Date:
02/25/2025
Applicant:
Brad Lowe
Description:
SOW FOR TUC30_072 Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (2) RRH units inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 21’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Existing 1.5” conduit for power to be intercepted and ran to new RRH cabinet – trench approx. 26’-0”. Install new 1.5” conduit for power from new RRH cabinet to existing pole – trench approx. 50’-0”.
Permit Reviews
Permit Number - TR-SWF-0225-00045
Permit Status: Complete
Permit Description: SOW FOR TUC30_072
Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (2) RRH units inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 21’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Existing 1.5” conduit for power to be intercepted and ran to new RRH cabinet – trench approx. 26’-0”. Install new 1.5” conduit for power from new RRH cabinet to existing pole – trench approx. 50’-0”.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/03/2025 | SMALL WIRELESS FACILITIES REVIEW v.2 | 04/16/2025 | APPROVED |
| 02/28/2025 | SMALL WIRELESS FACILITIES REVIEW v.1 | 03/25/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-SWF-0225-00045
Permit Status: Complete
Permit Description: SOW FOR TUC30_072
Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (2) RRH units inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 21’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Existing 1.5” conduit for power to be intercepted and ran to new RRH cabinet – trench approx. 26’-0”. Install new 1.5” conduit for power from new RRH cabinet to existing pole – trench approx. 50’-0”.
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 04/04/2025 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO ADA RAMPS ACCESSABLE. |
| 04/04/2025 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-SWF-0225-00045
Permit Description: SOW FOR TUC30_072
Remove existing antenna and RRHs. Install (1) canister antenna on new mount. Install (2) RRH units inside (1) RRH cabinet. Install (1) RRH cabinet on concrete slab. Install new 4” conduit for fiber from existing AT&T fiber meet vault to new RRH cabinet – trench approx. 21’-0”. Install new 4” conduit for coax from new RRH cabinet to existing pole – trench approx. 50’-0”. Existing 1.5” conduit for power to be intercepted and ran to new RRH cabinet – trench approx. 26’-0”. Install new 1.5” conduit for power from new RRH cabinet to existing pole – trench approx. 50’-0”.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2025 | TRSP - SWF - Preconstruction Meeting | Passed | Held pre-con over the phone | |
| 10/20/2026 | TRSP - SWF - Final | Passed | Work is complete |