Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-1124-01358
Permit Details
Apply Date:
11/22/2024
Applicant:
Andrew Ruiz
Description:
**24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** (Updated per Comment Responce Letter)
Permit Reviews
Permit Number - TR-ROW-1124-01358
Permit Status: Complete
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** (Updated per Comment Responce Letter)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/25/2024 | RIGHT-OF-WAY REVIEW v.1 | 11/27/2024 | REQUIRES RESUBMIT |
| 12/03/2024 | RIGHT-OF-WAY REVIEW v.2 | 12/04/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-1124-01358
Permit Status: Complete
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** (Updated per Comment Responce Letter)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 11/25/2024 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 11/25/2024 | Traffic control set-up approved between 9AM - 3:30PM |
| 11/26/2024 | The following extended traffic control set-up times were approved: for Hard Closure on Glenn St for 24 hrs- Work to be maintained to the 9 am - 3:30 pm Collector work hours.. |
| 11/26/2024 | Multiple cuts means more than one and by the same permit. If multiple cuts and patches are made to the same street and within the existing pavement, the street surface for the duration of the cuts and patches shall be milled 2-inches and overlaid with 2-inches of a City approved asphalt mix on arterial and collector streets. For non-moratorium residential streets, if multiple cuts are made to the same street and within the same block (intersection to intersection), an approved SEAL COAT treatment shall be added to the surface of the patched area for the entire width of lane affected between cuts upon completion of the pavement patch in lieu of a mill and overlay. In residential areas, the treatment shall extend to the center of the street. If both sides of the street have been cut, the entire street shall be covered over between the limits of the first cut to the last cut on the same respective street. |
| 11/26/2024 | Patch limits for pavements not under moratorium shall follow a T-Top Detail (Exhibit A). T-Top patches in concrete pavement will require Class P concrete. Class S concrete may be used for T-top patches in all other pavement types. The Utility Company shall apply an approved SEAL COAT PRODUCT to the affected patch area for 25-ft beyond the trench limits in all travel directions and for the width of the lane affected. The SEAL COAT product must have the following characteristics to be considered: • Asphalt seal coat (airport grade?) • Black emulsion • Polymer modified • Surface preparation per manufacturer • Application made per manufacturer • Curing time between 8-24 hrs • Thickness applications required |
Completed Inspections
Permit Status: Complete
Permit Number: TR-ROW-1124-01358
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** (Updated per Comment Responce Letter)
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2025 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 01/27/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 02/20/2025 | TRSP - ROW - Final | Passed | ||
| 01/06/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed |