Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Right-of-Way (ROW)
Address:
8360 E COOPER PL
Address NEW:
8360 E COOPER PL
Apply Date:
10/05/2026
Applicant:
Erica Goldston
Description:
Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.

Permit Reviews

Permit Number - TR-ROW-1026-01100
Permit Status: Inspections
Permit Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Start Date Submittal Complete Date Status  
10/05/2026 RIGHT-OF-WAY REVIEW v.1 10/28/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-1026-01100
Permit Status: Inspections
Permit Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Total Outstanding Activity Conditions - 3
Date Name
10/06/2026 Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvement and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced.
10/06/2026 **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14
10/06/2026 Traffic Control set-up approved between 7AM - 5PM

Outstanding Inspections

Permit Status: Inspections
Permit Number: TR-ROW-1026-01100
Permite Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting N/A Scheduled

Scheduled Inspections

Scheduled Inspections - TR-ROW-1026-01100
Status: Inspections
Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Scheduled Date Description Entered By Entered Date
11/23/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Scheduled
For information about today’s scheduled inspections please refer to the PDSD Daily Inspections Dashboards (Desktop) PDSD Daily Inspections Dashboards (Mobile) .

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
8360 E COOPER PL MAP_V1.PDF DOCUMENTS VIEW
8360 E. COOPER PL._V1.PDF DOCUMENTS VIEW