Permit: TR-ROW-1026-01100
Permit Details
Status:
Inspections
Type:
Right-of-Way (ROW)
Address:
8360 E COOPER PL
Address NEW:
8360 E COOPER PL
Apply Date:
10/05/2026
Applicant:
Erica Goldston
Description:
Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Permit Reviews
Permit Number - TR-ROW-1026-01100
Permit Status: Inspections
Permit Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/05/2026 | RIGHT-OF-WAY REVIEW v.1 | 10/28/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-1026-01100
Permit Status: Inspections
Permit Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 10/06/2026 | Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvement and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. |
| 10/06/2026 | **Pre-Activity Meeting w/Inspections **Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 – 42 Refer to COT 2015 Addition to the MUTCD section 14 |
| 10/06/2026 | Traffic Control set-up approved between 7AM - 5PM |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-ROW-1026-01100
Permite Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | N/A | Scheduled |
Scheduled Inspections
Scheduled Inspections - TR-ROW-1026-01100
Status: Inspections
Description: Hunter will be repairing 2 bench rehabs and 2 Manhole collars. We will also have UV (CIPP) lining installed for a sewer main.
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 11/23/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.