Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-0923-01181
Permit Details
Apply Date:
09/23/2023
Applicant:
Raquel Copado
Description:
Entrada para la casa
Permit Reviews
Permit Number - TR-ROW-0923-01181
Permit Status: Issued
Permit Description: Entrada para la casa
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/17/2023 | RIGHT-OF-WAY SIMPLE REVIEW v.2 | 10/24/2023 | APPROVED |
09/25/2023 | RIGHT-OF-WAY SIMPLE REVIEW v.1 | 09/29/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-ROW-0923-01181
Permit Status: Issued
Permit Description: Entrada para la casa
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
09/25/2023 | Curb Cuts and Driveways shall conform to the Following requirements in all residential zoned districts: Min Curb Cut width = 10 ft – Max Curb cut width 20 ft Max curb cut width for 2 adjoining properties = 30 ft Min distance between curb cuts = 12 ft Min distance of curb cut from street light standards, or catch basin = 5 ft Min distance of the curb cut from fire hydrant of City water hyrant = 20 ft Min distance of curb cut from end of curb return = 4 ft OR From a curb line or a cross street at a street intersection, whichever is more restrictive = 20 ft. |
09/25/2023 | Traffic Control set-up approved between 7AM - 5PM |
Completed Inspections
Permit Status: Issued
Permit Number: TR-ROW-0923-01181
Permit Description: Entrada para la casa
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2023 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
12/20/2023 | TRSP - ROW - SITE INSPECTION | Passed |