Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Right-of-Way (ROW)
Address NEW:
1895 E VALENCIA RD
Apply Date:
08/13/2026
Applicant:
Andres Amado
Description:
Replacement of one existing vault to bring up to current standards for manned access of 48in waterline . installation of second new vault for access to problematic and critical valve.

Permit Reviews

Permit Number - TR-ROW-0826-00894
Permit Status: Inspections
Permit Description: Replacement of one existing vault to bring up to current standards for manned access of 48in waterline . installation of second new vault for access to problematic and critical valve.
Start Date Submittal Complete Date Status  
08/14/2026 RIGHT-OF-WAY REVIEW v.1 09/03/2026 REQUIRES RESUBMIT Review Details
09/09/2026 RIGHT-OF-WAY REVIEW v.2 09/10/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0826-00894
Permit Status: Inspections
Permit Description: Replacement of one existing vault to bring up to current standards for manned access of 48in waterline . installation of second new vault for access to problematic and critical valve.
Total Outstanding Activity Conditions - 8
Date Name
08/18/2026 BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.
08/18/2026 Traffic control set-up approved between 9AM - 3:30PM
08/18/2026 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
08/18/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
08/18/2026 PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.
09/10/2026 All excavations shall be secured for safety at the end of each shift. If pedestrian access cannot be maintained, a temporary protected pedestrian route shall be provided. All open trenches shall be protected by Type II barricades with Type A flashers and surrounded by a barrier fence. Trenches deeper than 4 feet shall be surrounded by chain-link fence. Excavations may need to be covered with steel plates or other approved materials at the end of each shift.
09/10/2026 If survey markers are damaged or disturbed during construction, the contractor shall have the markers reset by a registered land surveyor in accordance with Arizona Revised Statutes (A.R.S.) ยง 33-103.
09/10/2026 The contractor shall restore all disturbed pavement in accordance with the City of Tucson Standard Specifications for Public Improvements and applicable standard details. All pavement patches shall match the existing pavement section and surface condition. The contractor shall maintain temporary patches in a safe and drivable condition until permanent restoration is completed. Any settlement, cracking, or pavement failure within the patched area shall be repaired by the contractor at no cost to the City for the duration of the warranty period.

Completed Inspections

Permit Status: Inspections
Permit Number: TR-ROW-0826-00894
Permit Description: Replacement of one existing vault to bring up to current standards for manned access of 48in waterline . installation of second new vault for access to problematic and critical valve.
Total Completed Inspections - 1
Date Description Inspector Results Comments
09/18/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
CAMPBELL TCP - NIGHTWORK REVISION_V2.PDF DOCUMENTS VIEW
DESIGN PLAN-202929 VALENCIA VAULTS FINAL PLANS-PRINT READY (3)-C1_V1.PDF DOCUMENTS VIEW
VALENCIA AND CAMPBELL MARKUPS_V1.PDF DOCUMENTS VIEW