Status:
Inspections
Type:
Right-of-Way (ROW)
Address NEW:
1815 E SPEEDWAY BL
Apply Date:
07/07/2026
Applicant:
Caitlin Ripley - Southwest Barricades
Description:
Speedway & Campbell Closures associated with UofA/Board of Regents new 9 story dorm (Helen closure by separate permit)

Permit Reviews

Permit Number - TR-ROW-0726-00793
Permit Status: Inspections
Permit Description: Speedway & Campbell Closures associated with UofA/Board of Regents new 9 story dorm (Helen closure by separate permit)
Start Date Submittal Complete Date Status  
07/08/2026 RIGHT-OF-WAY REVIEW v.1 07/10/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0726-00793
Permit Status: Inspections
Permit Description: Speedway & Campbell Closures associated with UofA/Board of Regents new 9 story dorm (Helen closure by separate permit)
Total Outstanding Activity Conditions - 6
Date Name
07/10/2026 The following extended traffic control set-up times were approved: 24hr Bike and Bus Lane Closure.
07/10/2026 Bike Lane Access and Accommodation 1) Posted Speeds 30 Mph or Less – Less than 14 lane - Use of the R4-11 alone is acceptable and preferred over Share The Road sign - 2) Posted Speeds 30 Mph or less – greater than 14 lane - Use of Share The Road sign is preferred 3) Posted Speeds 30 Mph or More – Any Lane Size - Provide a reasonable alternative for cyclists, such as a paved path, space behind barricades, or bike detour. Acceptable to direct cyclists to the sidewalk when properly signed depending on conditions 4) Bike lane to be maintained within Traffic Control closure and Share may Pedestrian detour path with proper R9-6 Sign.
07/10/2026 City of Tucson Right of Way Only ROW Permit is only allowed for work within City of Tucson Right of Way.
07/10/2026 Due to the presence of a bus stop in the area, the contractor is required to contact Joe Garcia, Sun Tran Dispatch, at 520-576-8726 no less than 48 business hours before beginning work to coordinate impacts.
07/10/2026 Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14
07/10/2026 Pre-Activity Meeting w/Inspections Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING

Completed Inspections

Permit Status: Inspections
Permit Number: TR-ROW-0726-00793
Permit Description: Speedway & Campbell Closures associated with UofA/Board of Regents new 9 story dorm (Helen closure by separate permit)
Total Completed Inspections - 3
Date Description Inspector Results Comments
08/28/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
09/04/2026 TRSP - ROW - SITE INSPECTION Passed verified barricade, set up jersey barriers and fencing, ADA ramp access at the east side of the barricade set up, running into a driveway at the west side of the barricade set up
10/01/2026 Required: Start Work Notice - Notify your DTM Inspector of your work start date. Notification only; you will be contacted if a Pre-Activity Meeting is needed. Passed barricade set up just checking to verify the set up and all corrections have been made

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
UOFA SPEEDWAY - LOGISTICS PLAN - V2_V1.PDF DOCUMENTS VIEW
UOFA SPEEDWAY - SW BARRICADE TRAFFIC CONTROL PLAN_V1.PDF DOCUMENTS VIEW