Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-0725-00913
Permit Details
Apply Date:
07/16/2025
Applicant:
Quail Construction Frank Cavazos
Description:
Installation of driveway aprons & sidewalk
Permit Reviews
Permit Number - TR-ROW-0725-00913
Permit Status: Inspections
Permit Description: Installation of driveway aprons & sidewalk
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/16/2025 | RIGHT-OF-WAY REVIEW v.1 | 07/17/2025 | REQUIRES RESUBMIT |
| 07/23/2025 | RIGHT-OF-WAY REVIEW v.2 | 07/28/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0725-00913
Permit Status: Inspections
Permit Description: Installation of driveway aprons & sidewalk
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 07/23/2025 | Your project work requires that you contact City of Tucson Park Tucson Department to alert them and coordinate work as needed in freight loading zones, parking garage access, areas with parking meters and/or other permitted parking areas. Notify Park Tucson (520-791-5071) at least 24 hours before starting work for any parking restrictions that may occur within the boundaries of South 22nd, North Speedway, West Grande and East Campbell. |
| 07/23/2025 | Refer to City of Tucson Transportation Manuals Chapter 25-38 - Residential Driveway Curb Cuts not to exceed 20' |
| 07/23/2025 | Pre-Activity Meeting Pre- activity meeting to be held 72 hrs in advance of work start with inspections.. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING |
| 07/23/2025 | Sec. 25-38. Special requirements in residential districts. (a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts: Minimum curb cut width . . . . . 10 feet Maximum curb cut width . . . . . 20 feet Maximum curb cut width for 2 adjoining properties . . . . . 30 feet Minimum distance between curb cuts . . . . . 12 feet Minimum distance of curb cut from street light standards, or catch basins . . . . . 5 feet Minimum distance of curb cut from a fire hydrant of city water hydrant . . . . . 20 feet Minimum distance of curb cut from end of a curb return . . . . . 4 feet OR from a curb line or a cross street at a street intersection, whichever is more restrictive . . . . . 20 feet |
| 07/23/2025 | Traffic Control set-up approved between 7AM - 5PM |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-ROW-0725-00913
Permite Description: Installation of driveway aprons & sidewalk
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2025 | TRSP - ROW - Paving - Subgrade/removal/placement | N/A | Re-inspection required | |
| 11/04/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | N/A | Re-inspection required | |
| 11/18/2025 | TRSP - ROW - Barricade Takedown | N/A | Re-inspection required | |
| 11/18/2025 | TRSP - ROW - Final | N/A | Re-inspection required |