Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW)
Address:
6780 E 3RD ST
Address NEW:
6780 E 3RD ST
Apply Date:
06/04/2024
Applicant:
Cameron Bonner
Description:
323068 Site 2 - Install Approximately 123LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench rehab's and new concrete collars will be completed on MH's 8427-32 and MH 8427-07 per PCRWRD standard detail 212. Traffic Control is for alley closure only.

Permit Reviews

Permit Number - TR-ROW-0624-00651
Permit Status: Complete
Permit Description: 323068 Site 2 - Install Approximately 123LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench rehab's and new concrete collars will be completed on MH's 8427-32 and MH 8427-07 per PCRWRD standard detail 212. Traffic Control is for alley closure only.
Start Date Submittal Complete Date Status  
06/04/2024 RIGHT-OF-WAY REVIEW v.1 06/05/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0624-00651
Permit Status: Complete
Permit Description: 323068 Site 2 - Install Approximately 123LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench rehab's and new concrete collars will be completed on MH's 8427-32 and MH 8427-07 per PCRWRD standard detail 212. Traffic Control is for alley closure only.
Total Outstanding Activity Conditions - 2
Date Name
06/04/2024 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
06/04/2024 Traffic control set-up approved between 9AM - 3:30PM

Outstanding Inspections

Permit Status: Complete
Permit Number: TR-ROW-0624-00651
Permite Description: 323068 Site 2 - Install Approximately 123LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench rehab's and new concrete collars will be completed on MH's 8427-32 and MH 8427-07 per PCRWRD standard detail 212. Traffic Control is for alley closure only.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/11/2024 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting N/A Re-inspection required

Completed Inspections

Permit Status: Complete
Permit Number: TR-ROW-0624-00651
Permit Description: 323068 Site 2 - Install Approximately 123LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench rehab's and new concrete collars will be completed on MH's 8427-32 and MH 8427-07 per PCRWRD standard detail 212. Traffic Control is for alley closure only.
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/11/2024 TRSP - ROW - Barricade - Setup/Routine Passed
09/11/2024 TRSP - ROW - Barricade Takedown Passed
09/11/2024 TRSP - ROW - Backfill - Placement/Compaction Passed
09/11/2024 TRSP - ROW - Final/Close-Out Passed