Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
In Review
Type:
Right-of-Way (ROW)
Address:
6251 S WILMOT RD
Address NEW:
6251 S WILMOT RD
Apply Date:
05/08/2026
Applicant:
Andrew Ruiz
Description:
Cathartic Protection upgrade. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will install a concrete slab and guard rail around the ground bed and anode J-box.

Permit Reviews

Permit Number - TR-ROW-0526-00556
Permit Status: In review
Permit Description: Cathartic Protection upgrade. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will install a concrete slab and guard rail around the ground bed and anode J-box.
Start Date Submittal Complete Date Status  
05/08/2026 RIGHT-OF-WAY REVIEW v.1 N/A IN REVIEW Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0526-00556
Permit Status: In review
Permit Description: Cathartic Protection upgrade. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will drill one-500’ deep by 10” diameter hole and will install anodes and backfill. Contractor will trench and install #2 copper positive header cable from the anode ground bed to the rectifier approximately 75’ away. Contractor will install a concrete slab and guard rail around the ground bed and anode J-box.
Total Outstanding Activity Conditions - 3
Date Name
05/14/2026 Traffic control set-up approved between 9AM - 3:30PM
05/14/2026 Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online.
05/14/2026 PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.