Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-0524-00603
Permit Details
Apply Date:
05/22/2024
Applicant:
Miguel Gonzalez
Description:
Maintance Permit: possible dig ups, for conduit crushed pipes. At existing Zayo HH locations an extra HH will be place. Begin at STA 0+00, by means pull through, pull fiber along existing Zayo conduits, with 288F micro cable. Place new Zayo HH at STA 1+10. Pull along Alameda St. to E Tools Ave. for approx. 1029' Place Zayo HH at STA 9+70. Resume pulling cable to STA 20+60. Place HH at STA 20+70. Resume pulling cable along existing ducts to STA 30+70. Place Zayo HH at STA 30+80, resume pulling cable to STA 44+90. Place Zayo HH at STA 45+00.
Permit Reviews
Permit Number - TR-ROW-0524-00603
Permit Status: Complete
Permit Description: Maintance Permit: possible dig ups, for conduit crushed pipes. At existing Zayo HH locations an extra HH will be place. Begin at STA 0+00, by means pull through, pull fiber along existing Zayo conduits, with 288F micro cable. Place new Zayo HH at STA 1+10. Pull along Alameda St. to E Tools Ave. for approx. 1029' Place Zayo HH at STA 9+70. Resume pulling cable to STA 20+60. Place HH at STA 20+70. Resume pulling cable along existing ducts to STA 30+70. Place Zayo HH at STA 30+80, resume pulling cable to STA 44+90. Place Zayo HH at STA 45+00.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/30/2024 | RIGHT-OF-WAY REVIEW v.2 | 07/16/2024 | APPROVED |
05/22/2024 | RIGHT-OF-WAY REVIEW v.1 | 05/22/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-ROW-0524-00603
Permit Status: Complete
Permit Description: Maintance Permit: possible dig ups, for conduit crushed pipes. At existing Zayo HH locations an extra HH will be place. Begin at STA 0+00, by means pull through, pull fiber along existing Zayo conduits, with 288F micro cable. Place new Zayo HH at STA 1+10. Pull along Alameda St. to E Tools Ave. for approx. 1029' Place Zayo HH at STA 9+70. Resume pulling cable to STA 20+60. Place HH at STA 20+70. Resume pulling cable along existing ducts to STA 30+70. Place Zayo HH at STA 30+80, resume pulling cable to STA 44+90. Place Zayo HH at STA 45+00.
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
05/30/2024 | This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Jodie Brown at Jodie.Brown@tucsonaz.gov with any questions. |
05/30/2024 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
05/30/2024 | Traffic control set-up approved between 9AM - 3:30PM |
06/06/2024 | For the section that starts at Toole Ave downtown and travels south to 22nd Street, the applicant will need archaeological monitor in any locations they plan to dig to find the existing conduit. In areas they are not digging and just pulling fiber optic through exiting conduit, they don’t need a monitor. The section south of 22nd to S Park they are fine with a waiver. |
06/10/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TR-ROW-0524-00603
Permit Description: Maintance Permit: possible dig ups, for conduit crushed pipes. At existing Zayo HH locations an extra HH will be place. Begin at STA 0+00, by means pull through, pull fiber along existing Zayo conduits, with 288F micro cable. Place new Zayo HH at STA 1+10. Pull along Alameda St. to E Tools Ave. for approx. 1029' Place Zayo HH at STA 9+70. Resume pulling cable to STA 20+60. Place HH at STA 20+70. Resume pulling cable along existing ducts to STA 30+70. Place Zayo HH at STA 30+80, resume pulling cable to STA 44+90. Place Zayo HH at STA 45+00.
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2024 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
10/22/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
10/21/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
10/22/2024 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
10/22/2024 | TRSP - ROW - Final/Close-Out | Passed |