Permit: TR-ROW-0426-00380
Permit Details
Apply Date:
04/01/2026
Applicant:
ANGEL MORALES
Description:
CIPP and replace existing concrete collars 05/13/2026- renew permit for 90 days as of 05/13/2026, new expiration date is 08/11/26
Permit Reviews
Permit Number - TR-ROW-0426-00380
Permit Status: Inspections
Permit Description: CIPP and replace existing concrete collars
05/13/2026- renew permit for 90 days as of 05/13/2026, new expiration date is 08/11/26
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/02/2026 | RIGHT-OF-WAY REVIEW v.1 | N/A | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0426-00380
Permit Status: Inspections
Permit Description: CIPP and replace existing concrete collars
05/13/2026- renew permit for 90 days as of 05/13/2026, new expiration date is 08/11/26
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 04/02/2026 | Traffic Control set-up approved between 7AM - 5PM |
| 04/06/2026 | Pre-Activity Meeting w/Inspections Pre- activity/construction meeting with City inspectors to be held 72 hours in advance of work start. Please request Inspections in your permit portal on TDC Online. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TR-ROW-0426-00380
Permite Description: CIPP and replace existing concrete collars
05/13/2026- renew permit for 90 days as of 05/13/2026, new expiration date is 08/11/26
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2026 | TRSP - ROW - Barricade - Setup/Routine | N/A | Partial Pass | |
| 05/13/2026 | TRSP - ROW - Final | N/A | Partial Pass | They did the site repair on the sewer in front of 33,19 and 3322 N. Park Ave. that has been completed. They still have collar work to do on park and E. Halcyon Rd. They are meeting with Pima county to find out if they are going to continue. They're waiting on parts for the collar. They will also be extending the permit or closing it. They will notify me today. |
Completed Inspections
Permit Status: Inspections
Permit Number: TR-ROW-0426-00380
Permit Description: CIPP and replace existing concrete collars
05/13/2026- renew permit for 90 days as of 05/13/2026, new expiration date is 08/11/26
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2026 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | sewer manhole cover replacement and a sewer pipe repair | |
| 05/13/2026 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 08/07/2026 | TRSP - ROW - Barricade - Setup/Routine | Passed | All work completed already Restoration of manholes and manhole covers | |
| 08/07/2026 | TRSP - ROW - Final | Passed | All work completed already Restoration of manholes and manhole covers |