Permit: TR-ROW-0424-00491
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW)
Address:
1110 N SILVERBELL RD
Address NEW:
1110 N SILVERBELL RD
Apply Date:
04/29/2024
Applicant:
Cameron Bonner
Description:
323065 Site 2 - EMC will need to repair an offset joint in the pipe located between 10ft and 15ft from the upstream manhole. Install Approximately 118 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench Rehab's and new concrete collars will be completed on MH's 3568-01 and MH 9897-10 per PCRWRD standard detail 211.
Permit Reviews
Permit Number - TR-ROW-0424-00491
Permit Status: Complete
Permit Description: 323065 Site 2 - EMC will need to repair an offset joint in the pipe located between 10ft and 15ft from the upstream manhole. Install Approximately 118 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehab's and new concrete collars will
be completed on MH's 3568-01 and MH 9897-10 per PCRWRD standard
detail 211.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/29/2024 | RIGHT-OF-WAY REVIEW v.1 | 05/01/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0424-00491
Permit Status: Complete
Permit Description: 323065 Site 2 - EMC will need to repair an offset joint in the pipe located between 10ft and 15ft from the upstream manhole. Install Approximately 118 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehab's and new concrete collars will
be completed on MH's 3568-01 and MH 9897-10 per PCRWRD standard
detail 211.
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 04/29/2024 | ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. |
| 04/29/2024 | Traffic control set-up approved between 9AM - 3:30PM |
Completed Inspections
Permit Status: Complete
Permit Number: TR-ROW-0424-00491
Permit Description: 323065 Site 2 - EMC will need to repair an offset joint in the pipe located between 10ft and 15ft from the upstream manhole. Install Approximately 118 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehab's and new concrete collars will
be completed on MH's 3568-01 and MH 9897-10 per PCRWRD standard
detail 211.
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 05/29/2024 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
| 08/09/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
| 08/09/2024 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 08/09/2024 | TRSP - ROW - Final/Close-Out | Passed |