Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-0324-00303
Permit Details
Apply Date:
03/18/2024
Applicant:
Caitlin Ripley
Description:
Sewer line failure in Dirt area between curb line and sidewalk, active sink hole in dirt. Work is be to dig access hole and perform a Cast Iron pipe rehabilitation using pipeline. Work is active and Foreman to meet with DTM Inspector Jeff Wingstrom on 3/19/2024.
Permit Reviews
Permit Number - TR-ROW-0324-00303
Permit Status: Issued
Permit Description: Sewer line failure in Dirt area between curb line and sidewalk, active sink hole in dirt. Work is be to dig access hole and perform a Cast Iron pipe rehabilitation using pipeline. Work is active and Foreman to meet with DTM Inspector Jeff Wingstrom on 3/19/2024.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/18/2024 | RIGHT-OF-WAY REVIEW v.1 | 03/18/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0324-00303
Permit Status: Issued
Permit Description: Sewer line failure in Dirt area between curb line and sidewalk, active sink hole in dirt. Work is be to dig access hole and perform a Cast Iron pipe rehabilitation using pipeline. Work is active and Foreman to meet with DTM Inspector Jeff Wingstrom on 3/19/2024.
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
03/18/2024 | Emergency – Active Working Progress – a TCP was not reviewed due to the nature of the work. Any legal questions related to this work shall be directed to Contractor to address since DTM did not have an opportunity to review, approve or inspect work. |
03/18/2024 | Traffic control set-up approved between 9AM - 3:30PM |
03/18/2024 | Pavement Patch type Shall Be in conformance to the current edition of the City of Tucson Public Utility Administrative Manual. |
03/18/2024 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 |
Completed Inspections
Permit Status: Issued
Permit Number: TR-ROW-0324-00303
Permit Description: Sewer line failure in Dirt area between curb line and sidewalk, active sink hole in dirt. Work is be to dig access hole and perform a Cast Iron pipe rehabilitation using pipeline. Work is active and Foreman to meet with DTM Inspector Jeff Wingstrom on 3/19/2024.
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/06/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
05/06/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
05/06/2024 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
05/06/2024 | TRSP - ROW - Final/Close-Out | Passed |