Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Right-of-Way (ROW)
Address NEW:
1810 W SAINT MARYS RD
Apply Date:
02/05/2026
Applicant:
Becky Hickox
Description:
WATERMAIN INSTALLATION - N CAMINO SANTIAGO AND W CALLE PLACIDA Contact is Geoff Ruffel 520-247-3640 (not in system) 3/16/26- 90 day renewal as of 3/18/26. NEW EXPIRATION 6/18/26

Permit Reviews

Permit Number - TR-ROW-0226-00157
Permit Status: Inspections
Permit Description: WATERMAIN INSTALLATION - N CAMINO SANTIAGO AND W CALLE PLACIDA Contact is Geoff Ruffel 520-247-3640 (not in system) 3/16/26- 90 day renewal as of 3/18/26. NEW EXPIRATION 6/18/26
Start Date Submittal Complete Date Status  
02/06/2026 RIGHT-OF-WAY REVIEW v.1 02/09/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0226-00157
Permit Status: Inspections
Permit Description: WATERMAIN INSTALLATION - N CAMINO SANTIAGO AND W CALLE PLACIDA Contact is Geoff Ruffel 520-247-3640 (not in system) 3/16/26- 90 day renewal as of 3/18/26. NEW EXPIRATION 6/18/26
Total Outstanding Activity Conditions - 2
Date Name
02/09/2026 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED. PER CITY CODE AND POLICY. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. Refer to COT Utility manual Page 41 - 42 Refer to COT 2015 Addition to the MUTCD section 14
02/09/2026 Traffic Control set-up approved between 7AM - 5PM

Outstanding Inspections

Permit Status: Inspections
Permit Number: TR-ROW-0226-00157
Permite Description: WATERMAIN INSTALLATION - N CAMINO SANTIAGO AND W CALLE PLACIDA Contact is Geoff Ruffel 520-247-3640 (not in system) 3/16/26- 90 day renewal as of 3/18/26. NEW EXPIRATION 6/18/26
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
TRSP - ROW - Final N/A Requested

Completed Inspections

Permit Status: Inspections
Permit Number: TR-ROW-0226-00157
Permit Description: WATERMAIN INSTALLATION - N CAMINO SANTIAGO AND W CALLE PLACIDA Contact is Geoff Ruffel 520-247-3640 (not in system) 3/16/26- 90 day renewal as of 3/18/26. NEW EXPIRATION 6/18/26
Total Completed Inspections - 3
Date Description Inspector Results Comments
03/06/2026 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
03/23/2026 TRSP - ROW - Barricade - Setup/Routine Passed 24 hour barricade set up at the fence for a road closure at the end of Ankum on the north west side of Saint Mary's at ankles it's a road closure sign for the new entrance to the development new housing development, which is also a PIA ///3/23/2026 new notes 24 hour barricade set up at the fence for a road closure at the end of Ankum on the north west side of Saint Mary's at ankles it's a road closure sign for the new entrance to the development new housing development, which is also a PIA did an inspection on the 23rd, which is today verified the flaggers certifications they are currently doing a crossing at North Camino Santiago. I will be doing the backfill inspection tomorrow.
03/25/2026 TRSP - ROW - Backfill - Placement/Compaction Passed 24 hour barricade set up at the fence for a road closure at the end of Ankum on the north west side of Saint Mary's at ankles it's a road closure sign for the new entrance to the development new housing development, which is also a PIA did an inspection on the 23rd, which is today verified the flaggers certifications they are currently doing a crossing at North Camino Santiago. I will be doing the backfill inspection tomorrow. backfill inspection completed just waiting on the permanent tee top patch

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW
26-0016B_V1.PDF DOCUMENTS VIEW
26-0016_V1.PDF DOCUMENTS VIEW
P25PW00153 TUMAMOC WATER PLAN - REVIEWED - ATC APPROVED_V1.PDF DOCUMENTS VIEW