Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW)
Address:
855 W WETMORE RD
Address NEW:
855 W WETMORE RD
Apply Date:
02/24/2025
Applicant:
Ash Smith
Description:
We will be performing seven (7) geotechnical borings within the roadway of Fairview Avenue from Fairview Avenue and Wetmore Road crossroads to Fairview Avenue and Prince Road crossroads, and seven (7) additional borings on Fairview Avenue from Fairview Avenue/Miracle Mile to Fairview Ave/Grant Rd for a Tucson Water waterline replacement project, for a total of 14 borings. The borings will be advanced with 7 or 8 inch hollow stem auger to a depth of approximately 10 feet below the ground surface. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along Fairview Avenue. Legal Contract Number 212603-04 Contact: Nathan Daou

Permit Reviews

Permit Number - TR-ROW-0225-00251
Permit Status: Complete
Permit Description: We will be performing seven (7) geotechnical borings within the roadway of Fairview Avenue from Fairview Avenue and Wetmore Road crossroads to Fairview Avenue and Prince Road crossroads, and seven (7) additional borings on Fairview Avenue from Fairview Avenue/Miracle Mile to Fairview Ave/Grant Rd for a Tucson Water waterline replacement project, for a total of 14 borings. The borings will be advanced with 7 or 8 inch hollow stem auger to a depth of approximately 10 feet below the ground surface. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along Fairview Avenue. Legal Contract Number 212603-04 Contact: Nathan Daou
Start Date Submittal Complete Date Status  
02/24/2025 RIGHT-OF-WAY REVIEW v.1 02/26/2025 REQUIRES RESUBMIT Review Details
03/19/2025 RIGHT-OF-WAY REVIEW v.3 03/20/2025 APPROVED Review Details
03/07/2025 RIGHT-OF-WAY REVIEW v.2 03/07/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0225-00251
Permit Status: Complete
Permit Description: We will be performing seven (7) geotechnical borings within the roadway of Fairview Avenue from Fairview Avenue and Wetmore Road crossroads to Fairview Avenue and Prince Road crossroads, and seven (7) additional borings on Fairview Avenue from Fairview Avenue/Miracle Mile to Fairview Ave/Grant Rd for a Tucson Water waterline replacement project, for a total of 14 borings. The borings will be advanced with 7 or 8 inch hollow stem auger to a depth of approximately 10 feet below the ground surface. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along Fairview Avenue. Legal Contract Number 212603-04 Contact: Nathan Daou
Total Outstanding Activity Conditions - 2
Date Name
02/24/2025 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRTIVE MANUAL **SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D.
02/24/2025 Traffic control set-up approved between 9AM - 3:30PM

Completed Inspections

Permit Status: Complete
Permit Number: TR-ROW-0225-00251
Permit Description: We will be performing seven (7) geotechnical borings within the roadway of Fairview Avenue from Fairview Avenue and Wetmore Road crossroads to Fairview Avenue and Prince Road crossroads, and seven (7) additional borings on Fairview Avenue from Fairview Avenue/Miracle Mile to Fairview Ave/Grant Rd for a Tucson Water waterline replacement project, for a total of 14 borings. The borings will be advanced with 7 or 8 inch hollow stem auger to a depth of approximately 10 feet below the ground surface. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along Fairview Avenue. Legal Contract Number 212603-04 Contact: Nathan Daou
Total Completed Inspections - 4
Date Description Inspector Results Comments
04/03/2025 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting Passed
04/29/2025 TRSP - ROW - Barricade - Setup/Routine Passed
05/01/2025 TRSP - ROW - Backfill - Placement/Compaction Passed
05/01/2025 TRSP - ROW - Final Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
LETTER_V1.PDF DOCUMENTS VIEW
TERRACON31 (002)_V1.PDF DOCUMENTS VIEW
TERRACON32 (002)_V1.PDF DOCUMENTS VIEW
INTERSECTION_V1.PDF DOCUMENTS VIEW
LOCATIONS_V1.PDF DOCUMENTS VIEW
TERRACON44_V1.PDF DOCUMENTS VIEW