Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW)
Address:
1109 W GLENN ST
Address NEW:
1109 W GLENN ST
Apply Date:
02/07/2025
Applicant:
Description:
**24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** Continuation permit TR-ROW-1124-01358 (Completion of Pavement Restoration Related to Scope of Work)

Permit Reviews

Permit Number - TR-ROW-0225-00182
Permit Status: Complete
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** Continuation permit TR-ROW-1124-01358 (Completion of Pavement Restoration Related to Scope of Work)
Start Date Submittal Complete Date Status  
02/07/2025 RIGHT-OF-WAY REVIEW v.1 02/11/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0225-00182
Permit Status: Complete
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** Continuation permit TR-ROW-1124-01358 (Completion of Pavement Restoration Related to Scope of Work)
Total Outstanding Activity Conditions - 6
Date Name
02/10/2025 The following extended traffic control set-up times were approved:
02/10/2025 PRE-CON/PAVEMENT/SIDEWALK
02/10/2025 Other Permits/Projects are or will be active in your project area. Please coordinate with the project manager in charge of any existing traffic control set-ups in your project area.
02/11/2025 Traffic control set-up approved between 9AM - 3:30PM
02/11/2025 Multiple cuts means more than one and by the same permit. If multiple cuts and patches are made to the same street and within the existing pavement, the street surface for the duration of the cuts and patches shall be milled 2-inches and overlaid with 2-inches of a City approved asphalt mix on arterial and collector streets. For non-moratorium residential streets, if multiple cuts are made to the same street and within the same block (intersection to intersection), an approved SEAL COAT treatment shall be added to the surface of the patched area for the entire width of lane affected between cuts upon completion of the pavement patch in lieu of a mill and overlay. In residential areas, the treatment shall extend to the center of the street. If both sides of the street have been cut, the entire street shall be covered over between the limits of the first cut to the last cut on the same respective street.
02/11/2025 Patch limits for pavements not under moratorium shall follow a T-Top Detail (Exhibit A). T-Top patches in concrete pavement will require Class P concrete. Class S concrete may be used for T-top patches in all other pavement types. The Utility Company shall apply an approved SEAL COAT PRODUCT to the affected patch area for 25-ft beyond the trench limits in all travel directions and for the width of the lane affected. The SEAL COAT product must have the following characteristics to be considered: • Asphalt seal coat (airport grade?) • Black emulsion • Polymer modified • Surface preparation per manufacturer • Application made per manufacturer • Curing time between 8-24 hrs • Thickness applications required

Completed Inspections

Permit Status: Complete
Permit Number: TR-ROW-0225-00182
Permit Description: **24 HOUR CLOSURE** Wallcon Plumbing will be entering Glenn St to extend water utilities to new facility.*** Continuation permit TR-ROW-1124-01358 (Completion of Pavement Restoration Related to Scope of Work)
Total Completed Inspections - 2
Date Description Inspector Results Comments
02/20/2025 TRSP - ROW - Backfill - Placement/Compaction Passed
02/20/2025 TRSP - ROW - Final Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
1110 W GLENN ST - HARD CL - SITE_V1.PDF DOCUMENTS VIEW
WALLCON - 1110 W GLENN ST - HARD CL REVISED TCP - GLENN STREET NEW BUILDING_V1.PDF DOCUMENTS VIEW
COMMENT RESPONSE LETTER - TR-ROW-1124-01358.PDF DOCUMENTS VIEW