Permit: TR-ROW-0224-00175
Permit Details
Status:
Complete
Type:
Right-of-Way (ROW)
Address:
7561 E POINCIANA DR
Address NEW:
7561 E POINCIANA DR
Apply Date:
02/16/2024
Applicant:
Cameron Bonner
Description:
323052 Site 2 - Install Approximately 416 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. Bench Rehabs and new concrete collars will be completed on MH's 7273-01 and 7272-26 per PCRWRD standard detail 211/212.
Permit Reviews
Permit Number - TR-ROW-0224-00175
Permit Status: Complete
Permit Description: 323052 Site 2 - Install Approximately 416 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehabs and new concrete collars will
be completed on MH's 7273-01 and 7272-26 per PCRWRD standard
detail 211/212.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/16/2024 | RIGHT-OF-WAY REVIEW v.1 | 02/21/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0224-00175
Permit Status: Complete
Permit Description: 323052 Site 2 - Install Approximately 416 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehabs and new concrete collars will
be completed on MH's 7273-01 and 7272-26 per PCRWRD standard
detail 211/212.
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 02/21/2024 | Traffic control set-up approved between 9AM - 3:30PM |
| 02/21/2024 | Pavement Patch type Shall Be in conformance to the current edition of the City of Tucson Public Utility Administrative Manual. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TR-ROW-0224-00175
Permite Description: 323052 Site 2 - Install Approximately 416 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehabs and new concrete collars will
be completed on MH's 7273-01 and 7272-26 per PCRWRD standard
detail 211/212.
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2024 | TRSP - ROW - Barricade - Setup/Routine | N/A | Re-inspection required | site complete |
| 05/28/2024 | TRSP - ROW - Paving - Subgrade/removal/placement | N/A | Re-inspection required | no asphalt restoration required |
| 05/28/2024 | TRSP - ROW - Backfill - Placement/Compaction | N/A | Re-inspection required | site complete backfill completed by Pima county |
Completed Inspections
Permit Status: Complete
Permit Number: TR-ROW-0224-00175
Permit Description: 323052 Site 2 - Install Approximately 416 LF of 8" Cured in Place Pipe. The
Cured in Place Pipe is a trench-less technology for sewer rehabilitation
and does NOT require disturbance of the earth. Bench Rehabs and new concrete collars will
be completed on MH's 7273-01 and 7272-26 per PCRWRD standard
detail 211/212.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 05/28/2024 | TRSP - ROW - Barricade Takedown | Passed | ||
| 05/28/2024 | TRSP - ROW - Final/Close-Out | Passed |