Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TR-ROW-0224-00143
Permit Details
Apply Date:
02/09/2024
Applicant:
Erica Goldston
Description:
The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St. Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\ Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Permit Reviews
Permit Number - TR-ROW-0224-00143
Permit Status: Issued
Permit Description: The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings
Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St.
Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\
Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/25/2024 | RIGHT-OF-WAY REVIEW v.1 | 06/26/2024 | REQUIRES RESUBMIT |
02/16/2024 | RIGHT-OF-WAY REVIEW v.3 | 02/21/2024 | APPROVED |
06/28/2024 | RIGHT-OF-WAY REVIEW v.2 | 07/01/2024 | REQUIRES RESUBMIT |
07/26/2024 | RIGHT-OF-WAY REVIEW REVISION v.2 | 07/26/2024 | REQUIRES RESUBMIT |
07/24/2024 | RIGHT-OF-WAY REVIEW REVISION v.1 | 07/24/2024 | REQUIRES RESUBMIT |
07/01/2024 | RIGHT-OF-WAY REVIEW v.3 | 07/08/2024 | APPROVED |
07/30/2024 | RIGHT-OF-WAY REVIEW REVISION v.3 | 08/01/2024 | APPROVED |
02/12/2024 | RIGHT-OF-WAY REVIEW v.2 | 02/13/2024 | REQUIRES RESUBMIT |
05/17/2024 | RIGHT-OF-WAY REVIEW v.2 | 05/21/2024 | APPROVED |
02/09/2024 | RIGHT-OF-WAY REVIEW v.1 | 02/09/2024 | REQUIRES RESUBMIT |
05/15/2024 | RIGHT-OF-WAY REVIEW v.1 | 05/15/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TR-ROW-0224-00143
Permit Status: Issued
Permit Description: The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings
Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St.
Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\
Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
02/09/2024 | BUS STOP IN AREA, CONTACT SUN TRAN DISPATCH AT 520-206-8934 AT LEAST 48-BUISNESS HOURS PRIOR TO START OF WORK FOR COORDINATION. |
02/09/2024 | Traffic Control set-up approved between 7AM - 5PM |
02/09/2024 | Traffic control set-up approved between 24 Hr |
02/09/2024 | Pavement Patch type Shall Be in conformance to the current edition of the City of Tucson Public Utility Administrative Manual. |
02/09/2024 | PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS PER MUTCD CHAPTER 6D. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 |
02/13/2024 | Your project work requires that you contact City of Tucson Environmental Services Department (520-791-3171) at least 24 hours prior to closing any street or alley. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TR-ROW-0224-00143
Permite Description: The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings
Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St.
Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\
Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
TRSP - ROW - Paving - Subgrade/removal/placement | N/A | Requested | ||
TRSP - ROW - Barricade Takedown | N/A | Scheduled | ||
10/21/2024 | TRSP - ROW - Final/Close-Out | N/A | Re-inspection required | |
10/21/2024 | TRSP - ROW - Concrete - Acceptance (Post-Pour) | N/A | Re-inspection required | |
10/21/2024 | TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) | N/A | Re-inspection required |
Completed Inspections
Permit Status: Issued
Permit Number: TR-ROW-0224-00143
Permit Description: The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings
Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St.
Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\
Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2024 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
05/31/2024 | TRSP - ROW - Barricade - Setup/Routine | Passed | ||
06/26/2024 | TRSP - ROW - SWBMP | Passed | ||
07/29/2024 | TRSP - ROW - Backfill - Placement/Compaction | Passed |
Scheduled Inspections
Scheduled Inspections - TR-ROW-0224-00143
Status: Issued
Description: The scope of work includes furnishing and installing approximately 900 linear feet of 8-inch DIP and 5,000 linear feet of 6-inch PVC water mains, 170 feet of 6”DIP, gate valves, cut & cap with drain valve assembly, fire hydrants, back flow prevention devices, water meter relocations and service connections. Pavement replacement as indicated on the drawings
Updated 5/17/2024 - Traffic Control plan updated to close both Southbound Lanes of Country Club between Flowing Wells and Glenn St.
Updated - 5/21/2024 - Request for 60 day Extension as of 5/26/2024 -\
Updated - 10/23/2024 - Request for 30 day Extension as of 10/23/2024
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
11/29/2024 | TRSP - ROW - Barricade Takedown | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)