Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW)
Address NEW:
68 N PLACITA DEL SACO
Apply Date:
01/09/2024
Applicant:
Cameron Bonner
Description:
323XX8 Site 1 - In order to install Install approximately 193 LF of 6" Cured in Place Pipe Ellison-Mills will need to remove and replace 10' of broken pipe 152' to 162' from MH 8485-09. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 8485-09 and MH 8485-06 per PCRWRD standard detail 211.

Permit Reviews

Permit Number - TR-ROW-0124-00050
Permit Status: Complete
Permit Description: 323XX8 Site 1 - In order to install Install approximately 193 LF of 6" Cured in Place Pipe Ellison-Mills will need to remove and replace 10' of broken pipe 152' to 162' from MH 8485-09. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 8485-09 and MH 8485-06 per PCRWRD standard detail 211.
Start Date Submittal Complete Date Status  
01/09/2024 RIGHT-OF-WAY REVIEW v.1 01/09/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ROW-0124-00050
Permit Status: Complete
Permit Description: 323XX8 Site 1 - In order to install Install approximately 193 LF of 6" Cured in Place Pipe Ellison-Mills will need to remove and replace 10' of broken pipe 152' to 162' from MH 8485-09. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 8485-09 and MH 8485-06 per PCRWRD standard detail 211.
Total Outstanding Activity Conditions - 1
Date Name
01/09/2024 Traffic Control set-up approved between 7AM - 5PM

Outstanding Inspections

Permit Status: Complete
Permit Number: TR-ROW-0124-00050
Permite Description: 323XX8 Site 1 - In order to install Install approximately 193 LF of 6" Cured in Place Pipe Ellison-Mills will need to remove and replace 10' of broken pipe 152' to 162' from MH 8485-09. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 8485-09 and MH 8485-06 per PCRWRD standard detail 211.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/09/2024 TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting N/A Re-inspection required

Completed Inspections

Permit Status: Complete
Permit Number: TR-ROW-0124-00050
Permit Description: 323XX8 Site 1 - In order to install Install approximately 193 LF of 6" Cured in Place Pipe Ellison-Mills will need to remove and replace 10' of broken pipe 152' to 162' from MH 8485-09. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 8485-09 and MH 8485-06 per PCRWRD standard detail 211.
Total Completed Inspections - 1
Date Description Inspector Results Comments
05/09/2024 TRSP - ROW - Notice of Completion Passed

Documents

File Name Document Type  
COT - TR - ROW PERMIT.PDF DOCUMENTS VIEW
3230X8 - SITE 1 FMP MAP (68 N PLACITA DEL SACO) -1_V1.PDF DOCUMENTS VIEW
DB 68878 - PAGE 1 - 87 N PLACITA DEL SACO - FOOTBALLS - 3230XX8_V1.PDF DOCUMENTS VIEW