Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Right-of-Way (ROW) - Annual
Address NEW:
6118 E CAMPOLINA TR
Apply Date:
06/22/2026
Applicant:
Cindy Nemo
Description:
Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493) DRIVEWAY/SIDEWALK Installation per SD200 and driveway per SD206

Permit Reviews

Permit Number - TR-ANN-0626-00155
Permit Status: Complete
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493) DRIVEWAY/SIDEWALK Installation per SD200 and driveway per SD206
Start Date Submittal Complete Date Status  
06/23/2026 RIGHT-OF-WAY REVIEW HOME DEVELOPER v.1 N/A APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TR-ANN-0626-00155
Permit Status: Complete
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493) DRIVEWAY/SIDEWALK Installation per SD200 and driveway per SD206
Total Outstanding Activity Conditions - 1
Date Name
06/23/2026 Traffic Control set-up approved between 7AM - 5PM

Outstanding Inspections

Permit Status: Complete
Permit Number: TR-ANN-0626-00155
Permite Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493) DRIVEWAY/SIDEWALK Installation per SD200 and driveway per SD206
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/14/2026 TRSP - ROW - Concrete - Acceptance (Post-Pour) N/A Re-inspection required three sidewalk panels west of driveway still need surface treatment for scratches

Completed Inspections

Permit Status: Complete
Permit Number: TR-ANN-0626-00155
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493) DRIVEWAY/SIDEWALK Installation per SD200 and driveway per SD206
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/01/2026 TRSP - ROW - Concrete - Subgrade/Forms (Pre-Pour) Passed Subgrade compaction and depths have been checked and verified, expansion joint, and safety caps are in place. Please see what can be done at cracked sidewalk panel where new is meeting existing
09/23/2026 TRSP - ROW - Concrete - Acceptance (Post-Pour) Passed treatment has been applied to damaged panels, grades have all been checked and verified, approved

Documents

File Name Document Type  
COT - TR - ROW PERMIT (SSRS).PDF DOCUMENTS VIEW