Permit Details

Status:
In Review
Type:
Fire Construction Permit
Address NEW:
1658 W VALENCIA RD
Apply Date:
02/17/2026
Applicant:
Jorge Pedrego
Description:
1. PROJECT DESCRIPTION THIS PROJECT CONSISTS OF MODIFICATIONS TO THE EXISTING FIRE ALARM SYSTEM AT VALLEY DISCOUNT. WORK INCLUDED IN THIS SCOPE IS LIMITED TO NOTIFICATION APPLIANCE REPLACEMENT AS DESCRIBED HEREIN. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL. 2. NOTIFICATION APPLIANCE MODIFICATIONS PROVIDE THE FOLLOWING MODIFICATIONS TO THE EXISTING NOTIFICATION APPLIANCES: REMOVE FIVE (5) EXISTING SYSTEM SENSOR WALL-MOUNTED SPEAKER/STROBES. FURNISH AND INSTALL FIVE (5) NEW SYSTEM SENSOR CEILING-MOUNTED SPEAKER/STROBES. NEW DEVICES SHALL CONNECT TO THE EXISTING NOTIFICATION CIRCUITS. 3. EQUIPMENT TO REMAIN AS-IS ALL EXISTING FIRE ALARM CONTROL PANELS, POWER SUPPLIES, INITIATING DEVICES, MODULES, WIRING, PATHWAYS, AND NOTIFICATION APPLIANCES NOT SPECIFICALLY IDENTIFIED IN THIS SCOPE SHALL REMAIN AS-IS. 4. WIRING EXISTING WIRING SHALL BE REUSED WHERE SUITABLE. MINOR WIRING MODIFICATIONS MAY BE PERFORMED AS REQUIRED TO SUPPORT THE RELOCATED NOTIFICATION APPLIANCES. 5. PROGRAMMING, TESTING, AND ACCEPTANCE PERFORM FUNCTIONAL TESTING OF THE REPLACED NOTIFICATION APPLIANCES. VERIFY PROPER SYSTEM OPERATION. COORDINATE FINAL INSPECTION AND ACCEPTANCE WITH THE AUTHORITY HAVING JURISDICTION (AHJ). 6. SCOPE LIMITATIONS WORK IS LIMITED TO ITEMS DESCRIBED HEREIN. DEVICES, SYSTEMS, OR SERVICES NOT SPECIFICALLY IDENTIFIED ARE EXCLUDED UNLESS ADDED BY APPROVED CHANGE ORDER.

Permit Reviews

Permit Number - TF-FCP-0226-00100
Permit Status: In review
Permit Description: 1. PROJECT DESCRIPTION THIS PROJECT CONSISTS OF MODIFICATIONS TO THE EXISTING FIRE ALARM SYSTEM AT VALLEY DISCOUNT. WORK INCLUDED IN THIS SCOPE IS LIMITED TO NOTIFICATION APPLIANCE REPLACEMENT AS DESCRIBED HEREIN. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN OPERATIONAL. 2. NOTIFICATION APPLIANCE MODIFICATIONS PROVIDE THE FOLLOWING MODIFICATIONS TO THE EXISTING NOTIFICATION APPLIANCES: REMOVE FIVE (5) EXISTING SYSTEM SENSOR WALL-MOUNTED SPEAKER/STROBES. FURNISH AND INSTALL FIVE (5) NEW SYSTEM SENSOR CEILING-MOUNTED SPEAKER/STROBES. NEW DEVICES SHALL CONNECT TO THE EXISTING NOTIFICATION CIRCUITS. 3. EQUIPMENT TO REMAIN AS-IS ALL EXISTING FIRE ALARM CONTROL PANELS, POWER SUPPLIES, INITIATING DEVICES, MODULES, WIRING, PATHWAYS, AND NOTIFICATION APPLIANCES NOT SPECIFICALLY IDENTIFIED IN THIS SCOPE SHALL REMAIN AS-IS. 4. WIRING EXISTING WIRING SHALL BE REUSED WHERE SUITABLE. MINOR WIRING MODIFICATIONS MAY BE PERFORMED AS REQUIRED TO SUPPORT THE RELOCATED NOTIFICATION APPLIANCES. 5. PROGRAMMING, TESTING, AND ACCEPTANCE PERFORM FUNCTIONAL TESTING OF THE REPLACED NOTIFICATION APPLIANCES. VERIFY PROPER SYSTEM OPERATION. COORDINATE FINAL INSPECTION AND ACCEPTANCE WITH THE AUTHORITY HAVING JURISDICTION (AHJ). 6. SCOPE LIMITATIONS WORK IS LIMITED TO ITEMS DESCRIBED HEREIN. DEVICES, SYSTEMS, OR SERVICES NOT SPECIFICALLY IDENTIFIED ARE EXCLUDED UNLESS ADDED BY APPROVED CHANGE ORDER.
Start Date Submittal Complete Date Status  
02/18/2026 FIRE CONSTRUCTION REVIEW v.1 N/A IN REVIEW Review Details